Error description
-
When using Index Builder with Library Integrity Utility with a HIDAM database, message: FABL3000E DYNALLOC FAILED FOR DDNAME: FABLICON DSNAME: nn.LICON RC=4 RSN=0410 is seen. The job abends with ABENDU3000 in FABLAI0 + x'5E4'. A few lines before message FABL3000E - following messages FABL0101I and FABL0102I. The first allocation of dataset nn.LICON was successful.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for Z/OS * * Release 1 (FMID=H27P110) users who use * * Integrity Checker utility * **************************************************************** * PROBLEM DESCRIPTION: When using Index Builder with Library * * Integrity Utility, message FABL3000E * * DYNALLOC FAILED FOR DDNAME: FABLICON * * RC=4 RSN=0410 is issued. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When using Index Builder with Library Integrity Utility, the following massage is issued. FABL3000E DYNALLOC FAILED FOR DDNAME: FABLICON DSNAME: xxxxxx RC=4 RSN=0410 The dynamic allocation for FABLICON fails, due to the duplicate DDNAME, if Library Integrity Utility is run twice within a same job step. Because Library Integrity Utility does not unallocate FABLICON in the termination process.
Problem conclusion
-
Library Integrity Utility is changed to unallocate the FABLICON dataset in the termination process.
Temporary fix
Comments
APAR Information
-
APAR number
PQ80434
-
Reported component name
IMS LIBR INTEG
-
Reported component ID
5655I4200
-
Reported release
110
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2003-11-04
-
Closed date
2003-11-10
-
Last modified date
2003-12-03
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UQ82032
Modules/Macros
-
FABLAI0 FABLAI3 FABLAT0 FABLIU00
Fix information
-
Fixed component name
IMS LIBR INTEG
-
Fixed component ID
5655I4200
Applicable component levels
-
R110 PSY UQ82032
UP03/11/13 P F311
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date:
03 April 2021