Error description

  • If we run Index Builder and it activates the Library Integrity
    Utility(LIU) we get the following error message:
    FABL0103W LIU INTEGRITY CHECKER DEACTIVATED
    The job ends with RC=00
    It is unclear why message FABL0103W is displayed.
    The sequence of message are as follows:
    +FABL0103W LIU INTEGRITY CHECKER DEACTIVATED
    +FABL0101I LIU INTEGRITY CHECKER NOW ACTIVE WITH LICON: nn.LICON
    +FABL0102I LIU INTEGRITY CHECKER INITIALIZATION COMPLETED
    +DFS035I BATCH INITIALIZATION COMPLETE  n101
    +FABL0105I LIU INTEGRITY CHECKER TERMINATION COMPLETED
    DFS627I IMS RTM CLEANUP ( EOT ) COMPLETE FOR ST nnn.mmm, RC=00
    

Local fix

  • 
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for Z/OS     *
    *                 Release 1 (FMID=H27P110) users who use       *
    *                 Integrity Checker utility                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When using Index Builder with Library   *
    *                      Integrity Utility, message FABL0103W    *
    *                      LIU INTEGRITY CHECKER DEACTIVATED       *
    *                      is issued.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When using LIU Data Integrity Utility without the global option
    module at installation level(LIU@INST), message FABL0103W
    is issued under the Index Builder or Image Copy utility
    independently of the IMS region controller.
    LIU Data Integrity Utility obtains IMSID in the System Contents
    Directory(SCD), and tries to load the global option module
    at IMS subsystem level(LIU@imsid).
    Because one of Index Builder tasks and Image Copy utility
    independently of the IMS region controller run without IMSID,
    the name of global option module at IMS subsystem level cannot
    be determined and this causes FABL0103W.
    

Problem conclusion

  • LIU Data Integrity Utility is changed to obtain the default
    IMSID in DFSVC000 if the name of global option module at IMS
    subsystem level cannot be determined.
    

Temporary fix

  • 
    

Comments

  • 
    

APAR Information

  • APAR number

    PQ80431

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2003-11-04

  • Closed date

    2003-11-11

  • Last modified date

    2003-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ82041

Modules/Macros

  •    FABLAH0  FABLAH06 FABLAH07 FABLAH08
    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R110 PSY UQ82041

       UP03/11/13 P F311

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.