Error description
ABENDS0C4 in compression routine DFSKMPX0 when using user header exit routine. The cause of the abend is that the chained save area for DFSKMPX0 is broken by the user header exit routine. HP Load expected to use the chained save area in the exit routine.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Load for * * OS/390 Release 1 (FMID=H1IM110). * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C4 occurs in the segment * * edit/compression routine when using the * * user header exit routine. The cause of * * the abend is that the chained save area * * for the segment edit/compression * * routine is broken by the user header * * exit routine. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** ABENDS0C4 occurs in the segment edit/compression routine that uses a two chained save area such as a sample segment edit/compression routine (DFSCMPX0) when using the user header exit routine. The cause of the abend is that the chained save area for the segment edit/compression routine is broken by the user header exit routine. HP Load expected to use the chained save area in the user header exit routine.
Problem conclusion
HP Load has been modified to re-chain the save area after calling the user header exit routine.
Temporary fix
Comments
APAR Information
APAR number
PQ79624
Reported component name
IMS HIGH PERF L
Reported component ID
5655E0700
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2003-10-15
Closed date
2003-10-19
Last modified date
2003-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ81261
Modules/Macros
HPSRHDLD HPSRHDL6 HPSRHDL7 HPSRHDL8 HPSRHSLD HPSRHSL6 HPSRHSL7 HPSRHSL8
Fix information
Fixed component name
IMS HIGH PERF L
Fixed component ID
5655E0700
Applicable component levels