A fix is available
APAR status
Closed as program error.
Error description
During the Collect/Update CS group data option, receive a -196 returning code out of IDLGINPT. It appears that an ABEND001 occured for DD TEMP01 because it was not closed properly.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL USERS OF DATABASE CONTROL SUITE R220 * **************************************************************** * PROBLEM DESCRIPTION: INVALID RETURN CODE -196 RECEIVED FROM * * PROGRAM IDLGINPT OR ABEND001 RC4 WITH * * MSGIEC020I DCB EROPT=ABE OR AN INVALID * * CODE, AND/OR NO SYNAD EXIT SPECIFIED * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** THE COLLECT PROCESS ENDED WITH A RETURN CODE -196 FROM MODULE IDLGINPT AND AN I/O ABEND001 RC4. IDLGINPT TRIED TO DO A READ/WRITE TO THE OUTPUT DATASET, TEMP01. BUT THE DATA SET WAS EMPTY AND HAD NOT BEEN SET WITH AN EOF. THE MISSING EOF CAUSED THE I/O FAILURE.
Problem conclusion
THE REXX EXEC IDLSMAIN CREATES AND ALLOCATES THE TEMP01 DATA SET FOR USE BY THE COLLECT MODULE IDLGINPT. AN EXECIO STATEMENT HAS BEEN ADDED TO IDLSMAIN TO OPEN/CLOSE THE TEMP01 DATASET WITH THE EOF.
Temporary fix
Comments
APAR Information
APAR number
PQ79322
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2003-10-07
Closed date
2003-12-01
Last modified date
2004-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ82675
Modules/Macros
IDLC0001 IDLSMAIN
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R220 PSY UQ82675
UP03/12/13 P F312
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date: