  • PROBLEM DESCRIPTION: Documentation changes to the User's
    Guide and sample members provided
                         the IRTSAMP library have not been
                         consistently provided and/or updated
                         for every IMS version.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users intending to install Program       *
    *                 Restart Facility for IMS with SMP/E and      *
    *                 IMS versions 5.1, 6.1, 7.1, and 8.1.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Documentation changes to the Program    *
    *                      Restart Facility User's Guide and       *
    *                      sample members provided in the IRTSAMP  *
    *                      library have not been consistently      *
    *                      provided and/or updated for every IMS   *
    *                      version.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Documentation changes to the Program Restart Facility User's
    Guide and sample members provided in the IRTSAMP library have
    not been consistently provided and/or updated for every IMS
    version. Also a new option IMSLOGR=IGNORE is being added to
    allow users to specify that Program Restart Facility should
    always ignore whatever is specified in the JCL.
    

Problem conclusion

  • This APAR updates Documentation in the Program Restart Facility
    User's Guide and refreshes all members in the IRTSAMP library,
    used to customize Program Restart Facility for IMS for use with
    IMS versions 5.1, 6.1, 7.1, and 8.1. This maintenance will also
    delete some sample members in IRTSAMP that are no longer
    supported, and some load modules which are no longer used. This
    maintenance also corrects a problem where an externally
    specified CKPTID is always ignored by Program Restart Facility.
    The code is being modified to use the CKPTID specified in the
    JCL if the restart CKPTID recorded by PRF is considered to be
    in doubt. Also a new option IMSLOGR=IGNORE is being added to
    allow users to specify the PRF should always ignore whatever
    is specified in the JCL.
    This APAR is being Held for REASON(ACTION) because some of the
    usermods modifying IMS target zones have changed and need to be
    restored before re-applying them. The optional usermods MRT510B,
    MRT610B, MRT710B, and MRT810B, if applied, will need to be
    restored followed by re-receiving them using the updated IRTSAMP
    members IRTUM51B, IRTUM61B, IRTUM71B, and IRTUM81B.
    This APAR is being Held REASON(DOC). The following text
    describes the documentation changes to the IBM Program Restart
    Facility for IMS User's Guide and Reference Version 2 Release 1:
    for Chapter 1, the section titled "Hardware Requirements"
    should read:
    Hardware Requirements
    Program Restart is designed to operate on any machime capable
    of operating IMS Versions 5,6,7, and 8.
    For Chapter 1, the section titled "Software Requirements"
    should read:
    Software Requirements
    Program Restart requires SMP/E for installation and supports
    IMS Versions 5,6,7, and 8.
    For Chapter 3, the first bullet item in the introductory
    paragraph for the chapter should read:
     Installing Program Restart using SMP/E and IMS Version
     5.1, 6.1, 7.1, or 8.
    For Chapter 3, the section titled "Installing Program Restart
    using SMP/E", the first paragraph should read:
    Installing Program Restart using SMP/E
    Program Restart can be installed with SMP/E on systems with
    IMS Version 5.1, 6.1, 7.1, and 8.1. The names of some of the
    install jobs and sample members are release dependent. To
    make things clear, the install instructions for each IMS
    version are presented separately here.
    For Chapter 3, the section titled "Installing Program Restart
    using SMP/E", the following text is added after the "IMS Version
    7.1" paragraph:
    IMS Version 8.1
    When using SMP/E to install on a system with IMS Release 8.1,
    follow these steps:
     Receive, Apply and Accept Program Restart using the
     instructions provided in the program directory.
     Apply SMP/E usermods MRT810A, MRT810B and MRT810D to your
     target IMS zone. Sample jobs IRTSR81A, IRTSR81B and IRTSR81D
     can be modified as necessary to receive the usermods.
     NEVER ACCEPT ANY OF THESE USERMODS INTO YOUR IMS DLIB ZONE.
     In all the SMP/E receive jobs, modify the //SMPCSI DD statement
     data set name to match the name of your SMP/E global CSI used
     to maintain your IMS zones. In addition, change the //SMPPTFIN
     DD statement to match the library name of your SIRTSAMP
     library. The members being received are IRTUM81A, IRTUM81B,
     and IRTUM81D.
     In all the SMP/E apply jobs, modify the //SMPCSI DD statement
     data set name to match the name of your SMP/E global CSI used
     to maintain your IMS zones and modify the IMSTZ81 target zone
     name to match the name of your IMS target zone. For job
     IRTSA81B, modify the //SIRTLOAD DD statement to match the
     SMP/E target data set name for the SIRTLOAD library. If you
     have a DDDEF defined for SDFSRESL, you can remove the
     //SDFSRESL DD statement: otherwise, modify the //SDFSRESL DD
     statement as required.
    For Chapter 3, the section titled "Maintaining Program Restart"
    should read as follows:
    Maintaining Program Restart
    If any maintainance is applied to the Program Restart target
    zone, it is necessary to reapply the Program Restart usermods
    into your IMS target zone as well. The usermods are:
     MRT510B and MRT510D if running with IMS Version 5.1
     MRT610B and MRT610D if running with IMS Version 6.1
     MRT710B and MRT710D if running with IMS Version 7.1
     MRT810B and MRT810D if running with IMS Version 8.1
    If any maintainance is applied to DFSRRC00, it is necessary to
    reapply usermod MRT510A, MRT610A, MRT710A, or MRT810A as well.
    Remember, do not accept any of the Program Restart usermods.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ76333

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2003-07-14

  • Closed date

    2003-09-03

  • Last modified date

    2003-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ79886

Modules/Macros

  • H23D210J IRT#CPID IRT#IGNR IRT#INCL IRTAINCL
    IRTALLOC IRTAOPT0 IRTAUSRL IRTDDA10 IRTDSL10 IRTHKIB0 IRTINCD0
    IRTIVACB IRTIVBMP IRTIVDBD IRTIVDLI IRTIVINI IRTIVOLC IRTIVPSB
    IRTIVS1M IRTIXT05 IRTIXT06 IRTIXT07 IRTIXT08 IRTPOS05 IRTPOS06
    IRTPOS07 IRTPOS08 IRTPRE00 IRTRCLST IRTRCZAP IRTRFE05 IRTRFE06
    IRTRFE07 IRTRFE08 IRTSA51A IRTSA51B IRTSA51D IRTSA61A IRTSA61B
    IRTSA61D IRTSA71A IRTSA71B IRTSA71D IRTSA81A IRTSA81B IRTSA81D
    IRTSR51A IRTSR51B IRTSR51D IRTSR61A IRTSR61B IRTSR61D IRTSR71A
    IRTSR71B IRTSR71D IRTSR81A IRTSR81B IRTSR81D IRTUM51A IRTUM51B
    IRTUM51C IRTUM51D IRTUM61A IRTUM61B IRTUM61C IRTUM61D IRTUM71A
    IRTUM71B IRTUM71C IRTUM71D IRTUM81A IRTUM81B IRTUM81C IRTUM81D
    IRTUPX00 IRTURRC0 IRTUX001 IRTWMSG0 IRTXIOA0 IRTXISPF IRTXRI05
    IRTXRI06 IRTXRI07 IRTXRI08 IRTXRST0 IRTXSC05 IRTXSC06 IRTXSC07
    IRTXSC08 IRTZSC05 IRTZSC06 IRTZSC07 IRTZSC08 IRTZSR05 IRTZSR06
    IRTZSR07 IRTZSR08 IRT9AJBS IRT9EINC IRT9VINC
    

Publications Referenced
SC27091001    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R210 PSY UQ79886

       UP03/09/05 P F309

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
24 January 2022