A fix is available
APAR status
Closed as program error.
Error description
Index record lengths of greater than three digits are not handled correctly, resulting in index completion code of A26.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Index Builder V2.3 users. * **************************************************************** * PROBLEM DESCRIPTION: Customer reported completion code A26 * * when rebuilding large record indexes. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** IB sort control module was creating three digits only LENGTH parameter of the sort RECORD control statement.
Problem conclusion
The module was fixed to create five digits LENGTH parameter.
Temporary fix
Comments
APAR Information
APAR number
PQ75460
Reported component name
IMS INDEX BUILD
Reported component ID
5655E2400
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2003-06-19
Closed date
2003-07-10
Last modified date
2003-08-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ78434
Modules/Macros
IIUBSCTL
Fix information
Fixed component name
IMS INDEX BUILD
Fixed component ID
5655E2400
Applicable component levels