A fix is available
APAR status
-
Closed as program error.
Error description
-
The input control statement SORTFSZ E15000 is being interpretted as 515000. When the value is packed, the character E, which is X'C5', ends up as 5.
Local fix
-
Omit the E. It is not needed. The value is already considered to be ESTIMATED.
Problem summary
-
**************************************************************** * USERS AFFECTED: This PTF does not affect general IMS Index * * Builder V2.3 functionalty. * **************************************************************** * PROBLEM DESCRIPTION: Customer reported that, when coding an * * E in front of the SORTFSZ control * * statement value, a 5 was added as the * * number's highest digit. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** IB User's guide clearly states that a numeric value is expected for this control statement. No check for numerics was made, so every character was packed.
Problem conclusion
-
SORTFSZ values are checked for numerics. If the check fails, control statement error is being reported and Index Builder abends.
Temporary fix
Comments
APAR Information
-
APAR number
PQ75273
-
Reported component name
IMS INDEX BUILD
-
Reported component ID
5655E2400
-
Reported release
230
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2003-06-13
-
Closed date
2003-07-10
-
Last modified date
2003-08-06
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UQ78430
Modules/Macros
-
IIUBINIT
Fix information
-
Fixed component name
IMS INDEX BUILD
-
Fixed component ID
5655E2400
Applicable component levels
-
R230 PSY UQ78430
UP03/07/11 P F307
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.