A fix is available
APAR status
Closed as new function.
Error description
ADD SUPPORT FOR THE FOLLOWING DBRC COMMANDS: CHANGE.PRILOG, CHANGE.SECLOG, DELETE.ALLOC, NOTIFY.PRILOG, NOTIFY.SECLOG
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Control Suite users. * **************************************************************** * PROBLEM DESCRIPTION: Add support for the following DBRC * * commands: * * CHANGE.PRILOG * * CHANGE.SECLOG * * DELETE.ALLOC * * NOTIFY.PRILOG * * NOTIFY.SECLOG * * INIT.PART * * CHANGE.PART * * DELETE.PART * * * * Change support for the following DBRC * * commands to handle HALDB options: * * CHANGE.DB * * DELETE.DB * * INIT.DB * * * * The following problems are also fixed * * in this APAR. * * 1. If the SETUP DEFINE function is * * repeated then the CS Groups shown on * * the SETUP COLLECT panel IDLSMAIP * * display the following incorrect * * COMMENTS text: * * "DBDLIB changed. Recollect CS Group". * * 2. Multiple AREA data set Fast Path * * databases have incorrect job steps * * built for them in image copy and reorg * * job streams. * * 3. HALDB Conversion Aid ISPF link * * does not connect. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** Support was added for the following DBRC commands: CHANGE.PRILOG CHANGE.SECLOG DELETE.ALLOC NOTIFY.PRILOG NOTIFY.SECLOG INIT.PART CHANGE.PART DELETE.PART The following DBRC commands were changed to handle HALDB options: CHANGE.DB DELETE.DB INIT.DB The following problems were also fixed in this APAR: 1. If the SETUP DEFINE function is repeated then the CS Groups shown on the SETUP COLLECT panel IDLSMAIP will still display the original correct value for the COMMENTS text. The COMMENTS text: "DBDLIB/DYNLIB changed. Recollect CS Group" will now only be displayed if the user changes the IMS DBDLIB and/or DYNLIB during the SETUP DEFINE function. 2. Image copy and reorg job streams for multiple AREA data set Fast Path databases will not contain superfluous job steps. 3. The HLQ parameter passed to the HALDB Conversion Aid Tool has been changed to match the new format needed by the HALDB . Conversion Aid Tool.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PQ66207
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2002-09-13
Closed date
2002-11-22
Last modified date
2002-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ72050
Modules/Macros
IDLCS11 IDLC0001 IDLC50 IDLGNJCX IDLH1672 IDLH1674 IDLICEC3 IDLICEDD IDLRDPA1 IDLRIDB6 IDLRIGS1 IDLRI612 IDLRI614 IDLRI640 IDLRI642 IDLRI644 IDLRI646 IDLRI648 IDLRI650 IDLRI652 IDLRI654 IDLRI656 IDLRI658 IDLRI660 IDLRI662 IDLRI664 IDLRI666 IDLRI668 IDLRI670 IDLRI672 IDLRI674 IDLRI750 IDLRI752 IDLRI754 IDLRI760 IDLRI762 IDLRI764 IDLRI766 IDLRI768 IDLRI770 IDLRI772 IDLRI774 IDLRI776 IDLRI778 IDLRI780 IDLRI782 IDLRI784 IDLRI786 IDLRI788 IDLRI790 IDLRI850 IDLRI852 IDLRI854 IDLRI856 IDLRI858 IDLRI984 IDLRI986 IDLRI988 IDLRI990 IDLRI992 IDLRI994 IDLRI996 IDLRJOB8 IDLRLIC1 IDLRLIDB IDLRLOG IDLRLOG1 IDLRLREC IDLRNOTI IDLRNPR1 IDLRNPR2 IDLRNPR3 IDLRNSE1 IDLRNSE2 IDLRNSE3 IDLRTAB1 IDLRUTIL IDLR52 IDLR53 IDLR54 IDLR55 IDLSMAIN IDLSOPT1 IDLSOPT3
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R220 PSY UQ72050
UP02/11/26 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date: