A fix is available
APAR status
Closed as program error.
Error description
In DB2 Admin Tool, using CX line command to CREATE INDEX in panel adb26 leads to panel adb26cxs where a prompt for PIECESIZE is left blank. SQLCODE104 results from the generated statement in which a default value is specified as PIECESIZE K . . Additional symptoms: sqlcode 104 -104 option 2.4 adb2e1 piece size msgdsnt408i DSNT408I SQLCODE = -104, ERROR: ILLEGAL SYMBOL "K". SOME SYMBOLS THAT MIGHT BE LEGAL ARE: <INTEGER> <BIG_INTEGER>
Local fix
Edit the CREATE INDEX statement before submitting for execution, or specify a valid value for PIECESIZE
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 ADMIN TOOL who use CX line * * command in panel ADB26 may be affected. * **************************************************************** * PROBLEM DESCRIPTION: Using CX line command to CREATE INDEX * * in panel ADB26 leads to panel ADB26CXS * * where a prompt for PIECESIZE is left * * blank. SQLCODE104 results from the * * generated statement in which a default * * value is specified as PIECESIZE K . * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** "CREATE INDEX WITH CX COMMAND WITH NO PIECESIZE VALUE" results in SQLCODE104
Problem conclusion
The following two problems are fixed: If PIECESIZE value not specified, option is generated anyway as 'PIECESIZE K' If PIECESIZE value not specified, but unit is indicated (K,M,G), option is incorrectly generated Both situations result in SQLCODE-104 when executed.
Temporary fix
Comments
APAR Information
APAR number
PQ65942
Reported component name
DB2 ADMIN TOOL
Reported component ID
568851500
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2002-09-05
Closed date
2002-10-16
Last modified date
2002-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ADB26CXS
Fix information
Fixed component name
DB2 ADMIN TOOL
Fixed component ID
568851500
Applicable component levels
R410 PSY UQ70910
UP02/10/23 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410"}]