IBM Support

PQ65766: FIXES: 1) IC TAKEN AT WRONG LOG POINT DUE TO MULT. OVERLAPPING INFLIGHT URIDS AND 2) ABEND ON TS'S W/PAGESIZE > 4K & INCR. IC.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This PTF fixes a problem where GGC selects an invalid point in
    the DB2 log with which to create an image copy for a given DB.TS
    and that DB.TS has  multiple, overlapping URIDs
    (Unit of Recovery Ids), one of which remains "inflight" when the
    IC is being created.
    
    An abends0c4 or abendu0016 involving processing incremental
    image copies of tablespaces with a pagesize > 4K.
    KEYWORDS
    s0c4 abend0c4 u0016 abend0016
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DB2 Change Accum Users                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This PTF fixes a problem where GGC      *
    *                      selects an invalid point in  the DB2    *
    *                      log with which to create an image copy  *
    *                      for a given DB.TS and that DB.TS has    *
    *                      multiple, overlapping URIDs             *
    *                      (Unit of Recovery Ids), one of          *
    *                      which remains "inflight" when the IC    *
    *                      is being created.                       *
    *                                                              *
    *                      An abends0c4 or abendu0016 involving    *
    *                      processing incrementalimage copies of   *
    *                      tablespaces with a pagesize > 4K.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A code change has been made to correct this problem.
    

Problem conclusion

  • APPLY PTF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ65766

  • Reported component name

    DB2 CHANGE ACCU

  • Reported component ID

    5655F5500

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2002-08-30

  • Closed date

    2002-10-03

  • Last modified date

    2002-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ70502

Modules/Macros

  •    GGC#ICAL GGC#LGAC GGC#LGAP
    

Fix information

  • Fixed component name

    DB2 CHANGE ACCU

  • Fixed component ID

    5655F5500

Applicable component levels

  • R120 PSY UQ70502

       UP02/10/09 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120"}]

Document Information

Modified date:
30 March 2021