APAR status
Closed as program error.
Error description
When using the Tab to move through the different components, it works fine (left->right, top->bottom). BUT, when you use Shift+Tab to try and go the other direction, it just sits there does nothing when it should go back to the previous component. Also when JComboBox is used within a JTable and when you Shift+Tab while editing a JComboBox it does move now, but it moves outside the table (the component that preceds the table in the order) instead of to the next cell in the table like it u to in Java 1.2.2.
Local fix
This problem can be resolved by backing out the fix for the link defect 41847.1 and by reintroducing the function isFocusTraversable( JComboBox c )in the file src\classes\sov\javax\swing\plaf\metal\MetalComboBoxUI.java
Problem summary
as above
Problem conclusion
Install any version of java with a build date of cn131-20020517 or later to obtain the fix
Temporary fix
Comments
APAR Information
APAR number
PQ60938
Reported component name
JAVA(1.3) COMMO
Reported component ID
5648C9800
Reported release
13W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2002-05-08
Closed date
2002-05-22
Last modified date
2002-05-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JAVA(1.3) COMMO
Fixed component ID
5648C9800
Applicable component levels
R31W PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.1","Edition":"","Line of Business":{"code":"","label":""}}]