Error description
MSGDFS0919I KEYLEN SPECIFICATION TOO SMALL. LEN SHOULD BE --0255 received running IBSCAN mode.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL IMS INDEX BUILDER V2.1 USERS WHO ARE * * RUNNING DATA BASES WITH CONCATENATED KEY * * LONGER THAN 208. ALL IMS INDEX BUILDER V2.1 * * USERS WHO ARE IMPLEMENTING THE SCAN METHOD * * TO REBUILD PRIMARY INDEXES. * **************************************************************** * PROBLEM DESCRIPTION: CUSTOMER RECEIVED DFS0919I WHILE * * IMPLEMENTING IBSCAN TO REBUILD * * SECONDARY INDEXES. CUSTOMER RECEIVED * * DFS643I WHILE IMPLEMENTING SCAN TO * * REBUILD PRIMARY INDEX. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** CONCATENATED KEY LENGTH OF CUSTOMER'S DATA BASE WAS LONGER THAN 208. THE ADDRESS PASSED TO DFSRRC00 AS APPLICATION PARAMETER FROM IB SCAN METHOD CONTAINED X'6B'.
Problem conclusion
IMS IB V2.1 SCAN PSBS ARE NOW BUILT WITH LARGE ENOUGH KEY LENGTH, APPLICATION PARMS ARE PASSED TO IMS IN NON-BINARY FORMAT.
Temporary fix
Comments
×**** PE02/08/23 FIX IN ERROR. SEE APAR PQ63030 FOR DESCRIPTION
APAR Information
APAR number
PQ60443
Reported component name
IMS INDEX BUILD
Reported component ID
5655E2400
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2002-04-23
Closed date
2002-05-13
Last modified date
2002-08-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ66167
Modules/Macros
IIUBINIM IIUBINI7 IIUBINI8 IIUBPRIM IIUBPR61 IIUBPR71 IIUBPR81 IIUSTART
Fix information
Fixed component name
IMS INDEX BUILD
Fixed component ID
5655E2400
Applicable component levels
R210 PSY UQ66167
UP02/05/15 P F205
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89M","label":"IMS Index Builder"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date:
04 October 2020