APAR status
Closed as program error.
Error description
Abend C4-11 in W.A. Task CSET EQQJHJCL at offset x'CF0' when OPC tries to clean an area previously getmained but that appears not available.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users Affected: * * ALL OPC USERS, * * FUNCTION=WA. * **************************************************************** * PROBLEM DESCRIPTION: Abend 0C4-11 in W.A. Task CSECT * * EQQJHJCL at level PQ43760. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** The customer sometimes receives an abend 0C4-11 in the Workstation Analyzer Task CSECT EQQJHJCL at offset x'CF0'. This happens because OPC tries to clear an area previously requested via the GETMAIN macro without checking the result of this macro.
Problem conclusion
The code was modified in order to be sure that the area requested is returned successfully by the GETMAIN macro when OPC tries to clear it. 102Y 202Y 302Y EQQJHJCL
Temporary fix
Comments
APAR Information
APAR number
PQ51719
Reported component name
TME 10 OPC V2 R
Reported component ID
5697OPC01
Reported release
202
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2001-08-24
Closed date
2001-08-27
Last modified date
2001-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ57185 UQ57186 UQ57192
Modules/Macros
EQQJHJCL
Fix information
Fixed component name
TME 10 OPC V2 R
Fixed component ID
5697OPC01
Applicable component levels
R102 PSY UQ57185
UP01/09/28 P F109
R202 PSY UQ57186
UP01/09/28 P F109
R302 PSY UQ57192
UP01/09/28 P F109
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"202","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2001