V2 PTF UQ55187 (v2 APAR PQ48231) did not correct the relink of ISPLINK into the ISPF dialog modules IRT9VINC, IRT9EINC and IRT9AJBS at installation time. In addition, code was added to IRT9AJBS (the job administration function) which prevented customers from viewing the restart information for jobs that were created with a CTDSHLQ specification greater than 8 characters in length
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS PGM RESTART V1 and V2 * **************************************************************** * PROBLEM DESCRIPTION: V1 PTF UQ55186 and V2 PTF UQ55187 (v1 * * APAR PQ48228 and V2 APAR * * PQ48231) did not correct the relink * * of ISPLINK into the ISPF dialog modules * * IRT9VINC, IRT9EINC and IRT9AJBS at * * installation time. In addition, * * code was added to IRT9AJBS (the job * * administration function) which * * prevented customers from viewing the * * restart information for jobs that * * were created with a CTDSHLQ * * specification greater than 8 characters * * in length as recommended in the user * * guide. * **************************************************************** * RECOMMENDATION: * **************************************************************** New function is being added as well as the following corrections: 1) Fix linkedit problem of ISPLINK at installation time which results in S0C1 for users of the ISPF dialog. 2) Remove confusing references to IRTLLIB in the IRTSAMP and IRTEXEC libraries since the installation guide does not refer to this library. 3) Allow users of the ISPF dialog who have specified a CTDSHLQ with a length greater than the recommended 8 characters to continue using their existing specification. 4) Add option '3' to main menu panel to directly edit the Inclusion Options data set. 5) Change the administer job list ISPF dialog function to refresh the job list after hitting the enter key instead of returning to the main menu each time. 6) Display a summary of any special restart options specified for a job on the administer job list screen. 7) Add line action SHOWID to display the restart checkpointID that will be selected by IMS PGM Restart the next time the job is run.
Problem conclusion
Fix linkedit problem of ISPLINK at installation and allow CTDSHLQ with a length greater than the recommended 8
Temporary fix
Comments
APAR Information
APAR number
PQ50712
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
210
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2001-07-18
Closed date
2001-07-24
Last modified date
2001-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ56303
Modules/Macros
IRTALLOC IRTJCLIN IRTPHELP IRTPH210 IRTPH211 IRTPH212 IRTPH213 IRTPH214 IRTPH215 IRTPH216 IRTPH300 IRTPJOBS IRTPPRIM IRTXISPF IRT9AJBS IRT9EINC IRT9VINC
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R210 PSY UQ56303
UP01/11/02 P F111 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date:
24 January 2022