Error description

  • After applying IMS V7 APAR PQ41116, High Performance Load job
    gets ABEND0C4 in DFSPCSH0 at offset x'39A' when it reloads HALDB
    with secondary indexing or logical relationships.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM IMS High Performance Load for OS/390 *
    *                 Release 1 users. (FMID=H1IM110)              *
    ****************************************************************
    * PROBLEM DESCRIPTION: After applying IMS V7 APAR PQ41116,     *
    *                      High Performance Load job for HALDB     *
    *                      with logical relationships or           *
    *                      secondary indexing gets ABEND0C4 in     *
    *                      DFSPCSH0 near the label PC17000 because *
    *                      JCBLEV1C is zero.                       *
    *                      Other possible symptom is ABEND0C4 in   *
    *                      DFSDBH00, ABEND0C1 or ABENDU3725.       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When reloading a HALDB with logical relationships or secondary
    indexing, High Performance Load uses IMS modules to create ILE
    (Indirect List Entry). IMS V7 APAR PQ41116 has changed DFSPCSH0
    to call DFSDVBH0 in the PC17000 subroutine. High Performance
    Load gets ABEND0C4 since it does not prepare the correct
    interface for the changed IMS code.
    

Problem conclusion

  • High Performance Load has been changed to tolerate the IMS V7
    change.
    You can apply the maintenance for this APAR before applying
    PQ41116. The new code runs under both level of IMS V7, before
    and after applying PQ41116.
    
    This APAR also includes code change to provide the report
    headers "MESSAGES" and "DBRC MESSAGES". These headers separate
    High Performance Load and DBRC messages printed to the SYSPRINT
    DD from other reports. Descriptions of the "MESSAGES" and "DBRC
    MESSAGES" report headers are not provided in this APAR since
    they are self-explanatory. The complete descriptions will be
    included into the next edition of High Performance Load User's
    Guide.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ45743

  • Reported component name

    IMS HIGH PERF L

  • Reported component ID

    5655E0700

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2001-02-01

  • Closed date

    2001-02-27

  • Last modified date

    2001-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ51843

Modules/Macros

  •    FABFLINK HPSCCPYR HPSCMSGS HPSCSMGR HPSRBFRM
    HPSRBITM HPSRCILE HPSRCIL7 HPSRCMPR HPSRCMP5 HPSRCMP6 HPSRCMP7
    HPSRDSCT HPSRFCA0 HPSRHALM HPSRHAL7 HPSRHDBD HPSRHDB7 HPSRHDLD
    HPSRHDL5 HPSRHDL6 HPSRHDL7 HPSRHRPT HPSRHRP7 HPSRHTBL HPSRLGSC
    HPSRLGS5 HPSRLGS6 HPSRLGS7 HPSRMAIN HPSRMSGS HPSRMSGT HPSROAFL
    HPSROSAM HPSRPDBD HPSRPDB5 HPSRPDB6 HPSRPDB7 HPSRPTRS HPSRPTR5
    HPSRPTR6 HPSRPTR7 HPSRRGL0 HPSRRLDM HPSRRLD7 HPSRRPRT HPSRRPR5
    HPSRRPR6 HPSRRPR7 HPSRRRIN HPSRRRI0 HPSRRRI9 HPSRRTI0 HPSRSMGR
    HPSRSQER HPSRSQE5 HPSRSQE6 HPSRSQE7 HPSRSRIN HPSRSRI5 HPSRSRI6
    HPSRUPDF HPSRUPD5 HPSRUPD6 HPSRUPD7 HPSRVSAM H1IM110J IMSRELS7
    ISCD6    ISCD7
    

Fix information

  • Fixed component name

    IMS HIGH PERF L

  • Fixed component ID

    5655E0700

Applicable component levels

  • R110 PSY UQ51843

       UP01/03/02 P F103

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]

Document Information

Modified date:
04 October 2020