APAR status
Closed as program error.
Error description
ABEND0C4 occurs in EQQXSSRR +2E0 when EQQXSSRR module is called recursively. This is the case when large volumes off PIF calls are issued.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of PIF. * * FUNCTION=PIF. * **************************************************************** * PROBLEM DESCRIPTION: Abend S0C4 in EQQXSSRR+X'2E0' due to a * * bad PHXS pointer. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** Abend S0C4 in EQQXSSRR+X'2E0' due to an invalid PHXS pointer. The reason is an invalid parameter list that is passed when the module is called recursively.
Problem conclusion
The missing parameters have been added to the parmlist, and a separate SRVDPTR is used for diagnostics gathered during the recursive call (diagnostics subsequently discarded). 102Y 202Y 302Y EQQXSSRR
Temporary fix
APAR fix CQ43022 has been sent to the customer, and is available on request from the C/T.
Comments
APAR Information
APAR number
PQ43022
Reported component name
TME 10 OPC V2 R
Reported component ID
5697OPC01
Reported release
302
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2000-11-06
Closed date
2000-12-14
Last modified date
2001-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ49587 UQ49588 UQ49589
Modules/Macros
EQQXSSRR
Fix information
Fixed component name
TME 10 OPC V2 R
Fixed component ID
5697OPC01
Applicable component levels
R102 PSY UQ49587
UP01/01/26 P F101
R202 PSY UQ49588
UP01/01/26 P F101
R302 PSY UQ49589
UP01/01/26 P F101
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"302","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]