IBM Support

PQ42973: ABEND WITHIN LOAD MODULE ASMA93 AT CSECT ASMA00+X'7D8' DUE TO CLI INSTRUCTION WITH INCORRECT ADDRESS IN R15

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When HLASM options are supplied via ddname ASMAOPT which refers
    to a sequential dataset, then ABENDS0C4 occurs in ASMA93 at
    offset 7D8 into csect ASMA00.
    

Local fix

  • Circumvention is to use PDS member to specify assembly options
    via ddname ASMAOPT.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All.                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. ABEND0C4 occurs at offset x'03E9B8'  *
    *                         within module ASMA93 when ASMAOPT    *
    *                         specifies a sequential dataset.      *
    *                      2. MSGASMA438N issued when invocation   *
    *                         parms agree with ASMAOPT parms.      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1. If the ASMAOPT DD statement refers to a sequential dataset,
       then an ABEND S0C4 occurs at offset x'7D8' within csect
       ASMA00 in module ASMA93. The failing machine instruction is
       9540F000 (CLI) caused by an incorrect value in Register 15.
    2. If an option provided in the ASMAOPT file is also provided on
       invocation or via the *PROCESS statement, then ASMA436N or
       ASMA437N or ASMA438N or ASMA439N is incorrectly issued when
       the values are identical.
       Additional keywords:
       MSGASMA436N MSGASMA437N MSGASMA438N MSGASMA439N
    

Problem conclusion

  • The High Level Assembler has been modified to:
    1a. Process ASMAOPT options when the ASMAOPT DD statement refers
        to a sequential dataset.
    1b. Issue new MSGASMA443N whenever ASMAOPT DD refers to a file
        with a record format of Undefined-length (ie. RECFM is U):
          "ASMA443N ASMAOPT record format invalid - options
                               provided via ASMAOPT ignored"
    2.  Only issue message ASMA436N ASMA437N ASMA438N or ASMA439N
        if the overriding options are different to those specified
        via the ASMAOPT file.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ42973

  • Reported component name

    HLASM MVS, VM &

  • Reported component ID

    569623400

  • Reported release

    140

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2000-11-03

  • Closed date

    2000-11-29

  • Last modified date

    2003-01-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ49056 UQ49057 UQ49058

Modules/Macros

  • $$ERR    ASMAINFO ASMA00   ASMA01   ASMA7DE
    ASMA7EN  ASMA7ES  ASMA7JP  ASMA7UE  ASMA9Z   MSGGEN
    

Publications Referenced
SC26494103    

Fix information

  • Fixed component name

    HLASM MVS, VM &

  • Fixed component ID

    569623400

Applicable component levels

  • R140 PSY UQ49057

       UP00/12/01 P F011

  • R340 PSY UQ49056

       UP00/11/30 P 0011

  • R489 PSY UQ49058

       UP00/11/30 P E251

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"140","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSENW6","label":"High Level Assembler and Toolkit Feature"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"140","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
17 January 2003