Error description
A CICS application has a help facility, which is invoked by hitting PF1. After upgrading maintenance the user cannot invoke the help panel. The following is seen in the NVAS log. EMS0620E MODULE EMSEPRMR. THE 3270 DATA STREAM CONTAINS INVALID DATA AT OFFSET EMS0620E X'000F', LU = EMSA4001,P0 = 4040,P1 = 7200, SENSE 0C06 EMS0620E DATA = X'40404040404040404040404040404040'.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All NV/AS users. * **************************************************************** * PROBLEM DESCRIPTION: Using an autologon (to a CICS appl) and * * hitting the PF1 key for help at the * * procedure end, in 3472-4 InfoWindow * * term environment, the procedure fails, * * NVAS issues the error msgEMS0620E * * (EMS0620E MODULE EMSEPRMR - 3270 DATA * * STREAM CONTAINS INVALID DATA AT OFFSET * * x'000F' SENSE=0C06). * * On the other cust term environment * * 3192G the same procedure works well. * * From the VTAM buffer trace the main * * item to be remarked is the real term * * 3472-4 sends no-AID x60 to NVAS, * * NVAS sends to the appl x88. In the * * 3192G case, NVAS forwards x60. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** In the 3472-4 InfoWindow real terminal environment, the PF1 key depressing for help at the end of an autologon to a CICS appl does not work; the same procedure works correctly in the 3192G real term env. At problem time NVAS changes the no-AID x60, received from the 3472-4 real term, with the x88 aid (structured field) and forwards this to the appl; the correct x60 data stream is forwarded to the appl in the 3192G case. The wrong case arises when NVAS misunderstands a previous structured field query reply stored in the server term virtual terminal control block with the no-AID just received from the real term, then it replaces the data stream and forwards it incorrectly.
Problem conclusion
Now NVAS checks for the no-AID x60 data stream when in the server term virtual term control block there is stored a previous x88 query reply structured field, and avoids to fall in the previous dangerous update, issuing a better check about the replacement aid routine.
Temporary fix
Comments
APAR Information
APAR number
PQ03456
Reported component name
NVAS/ESA MVS 2.
Reported component ID
569503601
Reported release
101
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1997-04-21
Closed date
1997-05-02
Last modified date
2016-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ04087
Modules/Macros
EMSETTUV
Fix information
Fixed component name
NVAS/ESA MVS 2.
Fixed component ID
569503601
Applicable component levels
R101 PSY UQ04087
UP97/05/05 P F705
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMX3","label":"Tivoli NetView Access Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"101","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 March 2016