Error description
NetView FTP 221 MVS server is always writing an SMF record to SMF dataset even if no SMF record number has been specified in the server initialization parameter file.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All NetView FTP users. * **************************************************************** * PROBLEM DESCRIPTION: The receiving NetView FTP MVS 221 * * server tries to write an SMF record * * even if the SMFREC parameter has not * * been specified in the list of * * initialization parameters. The number * * of the SMF record that is written is * * equal to 0. The cause of this wrong * * processing is unpredictable and is * * system dependant. Commonly an x'0C4' * * abend in module DVGMSFT could be * * issued. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** The NetView FTP MVS 221 receiving server always writes an SMF record with record number 0 even if the SMFREC initialization parameter has not been used.
Problem conclusion
The problem has been solved. The NetView FTP MVS 221 server will now check if a value has been specified for the SMFREC init parameters before attempting to write the SMF record. If the SMF writing will fail message DVG481I will be issued.
Temporary fix
Comments
APAR Information
APAR number
PN71477
Reported component name
NETVIEW/FTP MVS
Reported component ID
568510801
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1995-05-17
Closed date
1995-05-17
Last modified date
1995-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DVGCMID DVGMCZZ DVGMSFT
Fix information
Fixed component name
NETVIEW/FTP MVS
Fixed component ID
568510801
Applicable component levels
R230 PSY UN77383
UP95/06/25 P F506
Fix is available