IBM Support

PN70478: IF NVAS IS LOGAPPLED AND THE TERMINAL IS LOCKED WITH KEY, THEN TERMINAL GETS A BLANKS SCREEN INSTAED OF EMSP00 AFTER UNLOCK.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If NVAS is logappled and the terminal is locked with key, then
    terminal gets a blanks screen instead of Panel EMSP00 after
    unlock.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The problem occurs when a terminal,     *
    *                      LOGAPPLed to NVAS, is switched off, or  *
    *                      locked with the key, and then back on;  *
    *                      in this scenario, a blank screen is     *
    *                      displayed, and when the user presses    *
    *                      enter again, the USSMSG10.              *
    *                      The VTAM buffer trace shows:            *
    *                      1. terminal is powered on (unlocked)    *
    *                      2. CINIT and BIND from NVAS (query bit  *
    *                         is on).                              *
    *                      3. SDT and BID exchange                 *
    *                      4. Query request and query response     *
    *                      5. EMSP00 from NVAS                     *
    *                      6. terminal is locked with the key and  *
    *                         powered off and powered on again     *
    *                      7. CINIT and BIND from NVAS (query bit  *
    *                         is on).                              *
    *                      8. SDT exchange                         *
    *                      9. BID from NVAS results in -rsp with   *
    *                         sense 08020000 (terminal is locked)  *
    *                      EMS0596E EXCEPTION RESPONSE RECEIVED -  *
    *                           RTNCD = X04, FDBK2 = X04, SENSE =  *
    *                      EMS0596E    x08020000, LU = IVZTCM14.   *
    *                      10. terminal is unlocked and send a     *
    *                          LUSTAT to NVAS                      *
    *                      11. BID exchange successful             *
    *                      12. NVAS send 'F5C2114040'  that's all. *
    *                          So user has a blank screen.         *
    ****************************************************************
    * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR               *
    ****************************************************************
    The problem occurs when a terminal, LOGAPPLed to NVAS,
    is switched off, or locked with the key, and then back on;
    in this scenario, a blank screen is displayed, and when
    the user presses enter again, the USSMSG10.
    
    The problem is that when the LUSTAT is received and the BID is
    exchanged successfully, NVAS does not reissue a RPQ request but,
    because RIDT is in LOGONPAN status, it sends to the terminal
    what is stored in the VT (that is a blank screen), when it
    receives the ENTER from terminal it sends the unbind because it
    doesn't have the terminal characteristics returned with a "Query
    Reply".
    The solution is to start again the logon process when the RIDT
    is in LOGONPAN or FREERIDT statuts.
    

Problem conclusion

  • The problem is that when the LUSTAT is received and the BID is
    exchanged successfully, NVAS does not reissue a RPQ request but,
    because RIDT is in LOGONPAN status, it sends to the terminal
    what is stored in the VT (that is a blank screen), when it
    receives the ENTER from terminal it sends the unbind because it
    doesn't have the terminal characteristics returned with a "Query
    Reply".
    The solution is to start again the logon process when the RIDT
    is in LOGONPAN or FREERIDT statuts.
    

Temporary fix

  • Fix sent to the customer for field testing on 27/04/1995
    

Comments

  • Fix sent to customer for field test.
    

APAR Information

  • APAR number

    PN70478

  • Reported component name

    NVAS/ESA MVS 2.

  • Reported component ID

    569503601

  • Reported release

    101

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1995-04-20

  • Closed date

    1995-06-05

  • Last modified date

    2016-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UN77822

Modules/Macros

  • EMSEWR01
    

Fix information

  • Fixed component name

    NVAS/ESA MVS 2.

  • Fixed component ID

    569503601

Applicable component levels

  • R101 PSY UN77822

       UP95/06/06 P F506

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMX3","label":"Tivoli NetView Access Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"101","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 March 2016