IBM Support

PM99429: OmPE ABEND 0C4-004 NAME=FPEVRAC OFFSET=00010066 or OFFSET=0001006C

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer's got some 0C4-004 ABENDs - one by one - similar to
    this one:
    
    FPEV2102W  D2CP DB2 IFI RESPONSE TIME EXCEEDS MAX WAIT TIME BY
    110 SEC.
    . . .
    18.33.21 STC58927  FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
    18.33.21 STC58927  FPEV9999I LVLS/OMEGAMON XE PE/PM
    18.33.21 STC58927  FPEV9999I VALU/PCHK
    18.33.21 STC58927  FPEV9999I AB/S/0C4
    18.33.21 STC58927  FPEV9999I AB/U/000
    18.33.21 STC58927  FPEV9999I RIDS/FPEVRAC#l
    18.33.21 STC58927  FPEV9999I RIDS/UNKNOWN
    18.33.21 STC58927  FPEV9999I PTFS/N/A
    18.33.21 STC58927  FPEV9999I ADRS/N/A
    18.33.21 STC58927  FPEV9999I PSW /078D1000 BAB4496C
    18.33.21 STC58927  FPEV9999I REGS 0-1/00000000 33097488
    18.33.21 STC58927  FPEV9999I REGS 2-3/00000000 00000000
    18.33.21 STC58927  FPEV9999I REGS 4-5/00000000 00000000
    18.33.21 STC58927  FPEV9999I REGS 6-7/00000000 00000004
    18.33.21 STC58927  FPEV9999I REGS 8-9/33097758 4D84AF58
    18.33.21 STC58927  FPEV9999I REGS A-B/00000004 32E05070
    18.33.21 STC58927  FPEV9999I REGS C-D/BAB448A0 32E05070
    18.33.21 STC58927  FPEV9999I REGS E-F/BAB35762 BAB448A0
    18.33.22 STC58927  KO2O1352I D2G2> -START TRACE (MON)  DEST(OP2)
    CLASS( 1) BUFSIZE(1024)                         (DISPCMD )
    18.33.22 STC58927  FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
    18.33.22 STC58927  FPEV9999I LVLS/OMEGAMON XE PE/PM
    18.33.22 STC58927  FPEV9999I VALU/PCHK
    18.33.22 STC58927  FPEV9999I AB/S/0C4
    18.33.22 STC58927  FPEV9999I AB/U/000
    18.33.22 STC58927  FPEV9999I RIDS/FPEVRAC#l
    18.33.22 STC58927  FPEV9999I RIDS/UNKNOWN
    18.33.22 STC58927  FPEV9999I PTFS/N/A
    18.33.22 STC58927  FPEV9999I ADRS/N/A
    18.33.22 STC58927  FPEV9999I PSW /078D0000 BC8BE966
    18.33.22 STC58927  FPEV9999I REGS 0-1/00000000 330FE488
    18.33.22 STC58927  FPEV9999I REGS 2-3/00000000 00000000
    18.33.22 STC58927  FPEV9999I REGS 4-5/00000000 00000000
    18.33.22 STC58927  FPEV9999I REGS 6-7/8001BEF8 00000004
    18.33.22 STC58927  FPEV9999I REGS 8-9/330FE758 4C979F58
    18.33.22 STC58927  FPEV9999I REGS A-B/00000004 32D92620
    18.33.22 STC58927  FPEV9999I REGS C-D/BC8BE8A0 32D92620
    18.33.22 STC58927  FPEV9999I REGS E-F/BC8AF762 BC8BE8A0
    18.33.23 STC58927  KO2O1352I D2G2> -START TRACE(PERFM)
    TDATA(CORRELATION,CPU,DIST) CLASS(30) IFCID(105,107,172,1
    (DISPCMD )
    18.33.23 STC58927  KO2O1352I D2G2> 96) DEST(OP2) BUFSIZE(1024)
    (DISPCMD )
    18.33.23 STC58927  KO2O1309I NEAR-TERM HISTORY DATA COLLECTOR
    SERVER KO2ISRVB D2G2 IS ACTIVE (SERVINIE)
    18.33.23 STC58927  IDI0123S Processing of abend S0C4 terminated
    due to unsupported  612
       612             execution environment: Concurrent analysis in
    the address space
    18.33.23 STC58927  IEA995I SYMPTOM DUMP OUTPUT  613
       613             SYSTEM COMPLETION CODE=0C4  REASON
    CODE=00000004
       613              TIME=18.33.22  SEQ=09145  CPU=0000
    ASID=0052
       613              PSW AT TIME OF ERROR  078D0000   BC8BE966
    ILC 4  INTC 04
       613                ACTIVE LOAD MODULE
    ADDRESS=3C8AE900  OFFSET=00010066
       613                NAME=FPEVRAC
       613                DATA AT PSW  3C8BE960 - 80005860  90481EA6
    50706000
       613                GR 0: 00000000   1: 330FE488
       613                   2: 00000000   3: 00000000
       613                   4: 00000000   5: 00000000
       613                   6: 8001BEF8   7: 00000004
       613                   8: 330FE758   9: 4C979F58
       613                   A: 00000004   B: 32D92620
       613                   C: BC8BE8A0   D: 32D92620
       613                   E: BC8AF762   F: BC8BE8A0
       613              END OF SYMPTOM DUMP
    . . .
    At that OmPE continued monitoring...
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    *                 - TEP                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: In case the OMPE collector is running   *
    *                      on a highly utilized LPAR IFI request   *
    *                      timeouts might occur.                   *
    *                      These timeouts are reported in the      *
    *                      SYSPRINT via FPEV2102W messages, e.g.   *
    *                      DB2 IFI RESPONSE TIME                   *
    *                      EXCEEDS MAX WAIT TIME BY 110 SEC.       *
    *                      In this environment setup the READA     *
    *                      collector support task(FPEVRAC) might   *
    *                      abend with 0C4-004                      *
    *                      if DB2 message monitoring is enabled.   *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    In case OMPE collector is running on a highly utilized LPAR
    DB2 message monitor has to perform additional checks prior
    to accessing memory.
    
    PROBLEM CONCLUSION:
    Perform additional checks in DB2 MESSAGES collector prior to
    access memory.
    
    KEYWORDS:
    FPEB2102W DB2 MESSAGES COLLECTOR HIGH SYSTEM UTILIZATION
    
    CIRCUMVENTION:
    Disable DB2 message monitoring on highly utilized LPARs if
    FPEV2102W messages are present and FPEVRAC abends with 0C4.
    

Problem conclusion

  • Perform additional checks in DB2 MESSAGES collector prior to
    access memory.
    
    KEYWORDS:
    FPEB2102W DB2 MESSAGES COLLECTOR HIGH SYSTEM UTILIZATION
    
    CIRCUMVENTION:
    Disable DB2 message monitoring on highly utilized LPARs if
    FPEV2102W messages are present and FPEVRAC abends with 0C4.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM99429

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-18

  • Closed date

    2013-11-07

  • Last modified date

    2014-01-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI12276

Modules/Macros

  • DGOVMSTR DGOVM001 DGOVM002 FPEUMSGS FPEVM000
    FPEVOPM  FPEVRAC  FPEVSDCM FPEVSETM FPEVSPMM
    

Publications Referenced
GH12696500    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI12276

       UP13/11/14 P F311

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
15 January 2014