A fix is available
APAR status
Closed as program error.
Error description
User is running multiple instances of OMPE on the same LPAR. Auto Ops is starting all sessions concurrently. One session fails to initialize with the following messages KO2Z035I OM03 V511 Server virtual storage limit MEMLIMIT(NOLIMIT) setting discovered KO2Z028E OM03 V511 START service request error RC=0028 RSN=80000064 KO2Z999E OM03 V511 Service error SSM=OMPETOP /OMPEISX ABEND=U2008 RSN=80000064 MODE=ABEND IEA794I SVC DUMP HAS CAPTURED: 664 DUMPID=001 REQUESTED BY JOB (OMEGSO22) DUMP TITLE=OM03 SERVER ERROR CID=DB2OM STC=OMEGSO22 SSM=OMPETOP /OMPEISX ABEND=U2008 RSN=80000064 MODE=ABEND ABEND U2008 RC=28 RSN=00000064 may occur when multiple versions of the OMPE Collector subsystem are simultaneously started. The problem is caused due to an invalid major name specified on the ENQ/DEQ MVS service request macro. Additional Keywords OMPEISX 80000064 U2008 0028 OMPETOP
Local fix
Allow 5 to 10 seconds delay between issuing start commands for subsequent OMPE tasks running on the same LPAR
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: Duplicate subsystem name assignment * * causes errors during initialization * * processing. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Dynamic subsystem name assignement fails to detect duplicate subsystems. PROBLEM CONCLUSION: Assign unique subsystem name to initializing OMPE Collector started task. KEYWORDS: U2008 KO2Z028E
Problem conclusion
Assign unique subsystem name to initializing OMPE Collector started task. KEYWORDS: U2008 KO2Z028E
Temporary fix
Comments
APAR Information
APAR number
PM99020
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-10-14
Closed date
2013-12-04
Last modified date
2014-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI13198 UI13197
Modules/Macros
KO2ZREQ KO2ZSSN
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 January 2014