PM98181: SELECTOR FAILS WITH EKYB322E AFTER PM83491 / UK92713 APPLIED 13/11/12 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Selector fails with EKYB322E after PM83491 / UK92713 applied.
    EKYB322E NONZERO CODE RETURNED BY MACRO DYNALLOC WHEN RETRIEVING
    JCL ALLOCATION RESOURCES
              RETURN CODE (R15): X'00000004'/4
              DSNAME: SGZS1.IMS1.SLDSP.@D99N00.G0230V00
              ERROR REASON CODE: X'00000438'/1080
              ERROR INFORMATION CODE: X'00000000'/0
    EKYB343E ERROR OCCURED WHILE READING THE IMS LOG FILES
    EKYB401E SELECTOR EXECUTION FAILURE
    EKYB004I SELECTOR COMPLETED WITH RETURN CODE 16 AND REASON CODE4
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS DataPropagator Version 3        *
    *                 Release 1 asynchronous Selector component.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: After applying PTF UK92713 MSGEKYB322E  *
    *                      may be encountered when running the     *
    *                      Selector.                               *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    After applying PTF UK92713 MSGEKYB222E "NONZERO CODE RETURNED BY
    MACRO DYNALLOC..."  may be issued when running the Selector.
    

Problem conclusion

  • The problem resulted because the Selector considered IMS log
    records that are of no direct importance during the gathering of
    IMS changed data.  The possibility for this problem to occur was
    allowed a result of changes made to the Selector to satisfy
    earlier Selector APAR PM83491.  Maintenance associated with
    earlier Selector APAR PM83491 (PTF UK92713) allowed the leading
    edge processing time for the Selector to be moved forward, even
    when no records of interest to the Selector where encountered
    during a particular Selector run.  In order to satisfy the
    requirements of APAR PM83491, the Selector may consider IMS log
    records that have no direct relation to the capture of IMS
    changed data.
    The problem will not occur when the Selector is processing data
    from a single IMS subsystem.  The problem will also not occur
    when the Selector uses the IMS log subset CDSDS for processing
    input, regardless if processing logs from a single IMS subsystem
    or when merging IMS log data from multiple IMS subsystems.
    Stated differently, the problem may only occur when the Selector
    processes complete IMS logs (not CDCDS) from multiple IMS
    subsystems.
    In the revised code of the new fix for APAR PM98181, we
    continue to maintain the leading edge time stamp in order to
    continue to allow for resolution of prior APAR PM83491.
    However, only time stamps from records of interest to IMS change
    data capture processing and not other IMS log records will be
    considered when merging IMS replication log data, thus avoiding
    the reported problem.
    

Temporary fix

  • *********
    * HIPER *
    *********
    TEMPORARY FIX AVAILABLE FROM CHANGE TEAM.
    

Comments

APAR Information

  • APAR number

    PM98181

  • Reported component name

    IMS DATA PROPAG

  • Reported component ID

    5655E5200

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-01

  • Closed date

    2013-11-12

  • Last modified date

    2013-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI12437

Modules/Macros

  •    EKYB300X EKYB310X
    

Fix information

  • Fixed component name

    IMS DATA PROPAG

  • Fixed component ID

    5655E5200

Applicable component levels

  • R310 PSY UI12437

       UP13/11/15 P F311 ®

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: