Error description
ABENDS0C4 in HFPA5SR0 near x'4DA' followed by an ABENDU3006 when running Fast Path Advanced Analyzer while specifying SEGLDIST=YES for a particular database. U3006 S0C4
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool * * or Fast Path Online Tools in Fast Path * * Solution Pack Version 1 Release 2 * * (FMID: HAHQ120) who use SEGLDIST option. * **************************************************************** * PROBLEM DESCRIPTION: Abend S0C4 occurs in module HFPA5SR0 * * when running FPA Analyze or FPO Online * * Pointer Checker with SEGLDIST=YES. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the average length of a segment is extremely closed to the maximum length, and when SEGLDIST=YES is specified, FPA Analyze or FPO Online Pointer Checker abends with S0C4 in module HFPA5SR0. The cause of the abend is to calculate the range that contains more than 90% of segment occurrences incorrectly.
Problem conclusion
The FPA Analyze and the FPO Online Pointer Checker are modified to calculate the range that contains more than 90% of segment occurrences correctly.
Temporary fix
Comments
APAR Information
APAR number
PM97923
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-09-26
Closed date
2013-10-11
Last modified date
2013-11-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK98395
Modules/Macros
HFPA5SR0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R120 PSY UK98395
UP13/10/13 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date:
04 October 2020