IBM Support

PM97655: Print form output ends up on wrong row under certain circumstances

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a print form constant field ends exactly at the end of the
    line and another print form constant field follows, it is
    possible that the lines will be merged.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When a print form constant ended at the exact rhs of the
    line and another constant began at the next line, it was
    possible that these lines were merged and incorrect layout
    would occur. The logic needed to check for this condition
    and insert a new line command for the form. This was being
    done for variable fields, but wasn't for constant fields.
    

Problem conclusion

  • The software was updated. The check is now made for all
    types of fields.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM97655

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-23

  • Closed date

    2014-09-25

  • Last modified date

    2014-09-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R850 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
25 September 2014