IBM Support

PM97230: Repeated rows for calculations after upgrade

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In a report upgraded from 8.1, if two particular metrics are
    both dragged into the same query studio report (or RS list), the
    values are repeated over and over. This also causes the summary
    row to be inflated as well since they are all added up. ?In
    Cognos 8.1, the correct summary and number of rows were produced
    when running the report. Cognos 8.3 shows the correct number of
    rows, but with an inflated summary. Cognos 10.1.1 has the
    incorrect number of rows (many values repeated), as well as an
    inflated summary total.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos Business Intelligence 10.2 Fix Pack 3  *
    *  or upgrade to IBM Cognos Business Intelligence 10.2.1 Fix   *
    * Pack 3                                                       *
    ****************************************************************
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM97230

  • Reported component name

    COG QUERY STUDI

  • Reported component ID

    5724W12QS

  • Reported release

    A11

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-17

  • Closed date

    2014-04-30

  • Last modified date

    2014-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI34408

Fix information

  • Fixed component name

    COG QUERY STUDI

  • Fixed component ID

    5724W12QS

Applicable component levels

  • RA20 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWV","label":"Query Studio v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A11","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
20 June 2014