IBM Support

PM96722: CCF COMMAND PANEL RESULTS FOR /DIS POOL QBUF ARE MISSING LEADING CHARACTERS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IMS CMDDIS /DIS POOL QBUF output is not correct when entered
    through the CCF command panel.  The first three characters are
    missing.  Other display commands work correctly.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: ALL THE USERS USE IMS COMMAND CONTROL        *
    *                 FICILITIES VERSION 2.2 WITH APPC             *
    *                 ROUTING TECHNIQUE.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: ISPF COMMAND /DIS POOL QBUF             *
    *                      HAD A TRAUCATED DISPLAY RESULT.         *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    WITH THE COMMAND OF /DIS POOL QBUF, BECAUSE POOL
    QBUF HAS A DIFFERENT DATA TABLE STRUCTURE, IT
    SHOULD BE TREATED DIFFERENTLY THAN OTHER REGULAR
    DATA.
    

Problem conclusion

  • CCF MODULE CCFEXEC0 HAS BEEN MODIFIED TO NOT
    REMOVE THE FIRST 4 CHARACTERS IN THE DISPLAY,
    WHEN /DIS POOL QBUF IS RECEIVED.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM96722

  • Reported component name

    IMS COMMAND CTL

  • Reported component ID

    5655F4000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-09-10

  • Closed date

    2014-02-26

  • Last modified date

    2014-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI15496

Modules/Macros

  • CCFEXEC0
    

Fix information

  • Fixed component name

    IMS COMMAND CTL

  • Fixed component ID

    5655F4000

Applicable component levels

  • R220 PSY UI15496

       UP14/02/28 P F402

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY6","label":"IMS Command Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
21 October 2020