IBM Support

PM95893: RUNNING FABCUR1 RESULTS IN ABEND0C4 DUE TO LACK OF SAVE AREAS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FABCUR1 calls FABC1EXT which calls the compression routine exit.
    FABC1EXT only creates five save areas.  If more are needed
    the ABENDS0C4 will occur going off the end of the chain.
    The code will be modified to increase the number of save areas
    in the chain.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DEDB Unload Utility users of HPFPU       *
    *                 Fast Path Basic Tools in Fast Path Solution  *
    *                 Pack Version 1 Release 2 (FMID: HAHQ120).    *
    ****************************************************************
    * PROBLEM DESCRIPTION: DEDB Unload Utility (FABCUR1) fails     *
    *                      with ABENDS0C4.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    FABCUR1 calls FABC1EXT which calls the compression routine exit.
    FABC1EXT only prepares 5 save areas.
    When segment Edit/Compression exit routine and INIT parameter
    are specified in DBDGEN, ABENDS0C4 occurs if more than 5 save
    areas are needed for INIT call.
    

Problem conclusion

  • FABC1EXT has been modified to prepare 20 save areas for INIT
    call.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM95893

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-08-27

  • Closed date

    2013-09-19

  • Last modified date

    2013-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK97678

Modules/Macros

  • FABC1EXT
    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R120 PSY UK97678

       UP13/09/20 P F309

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 October 2013