Error description

  • DADSM OBTAIN macro for INZPLIB0 will fail if libraries are
    stored on an EAV volume and have the extended addressability
    attribute.
    The issue occurs if target load module libraries processed by
    INZPLIB0 (i.e. SINZLINK and SINZLOAD) has the EXTENDED
    attribute (available since z/OS 1.12). The issue does not
    occur if the target library resides on EAV volumes provided
    that it does not have the EXTENDED attribute.
    
    PB11995
    

Local fix

  • Consider using another dataclass that does not have the EXTENDED
    attribute.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 High Performance Unload.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: INZPLIB0 issues an OBTAIN MACRO not     *
    *                      compatible with EAV support and         *
    *                      undetermined synptom may occur. The     *
    *                      INFVSUT4 module is guilty.              *
    *                      The issue occurs if a target load       *
    *                      module libraries processed by INZPLIB0  *
    *                      (i.e. SINZLINK and SINZLOAD) has the    *
    *                      EXTENDED attribute (available since     *
    *                      z/OS 1.12). The issue does not occur    *
    *                      if the target library resides on EAV    *
    *                      volumes provided that it does not have  *
    *                      the EXTENDED attribute.                 *
    *                      PB 11195                                *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    The infvsut4 module was fixed.
    

Problem conclusion

Temporary fix

Comments

  • APPLY the PTF.
    

APAR Information

  • APAR number

    PM94708

  • Reported component name

    DB2 HI PERF UNL

  • Reported component ID

    5697F4400

  • Reported release

    410

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-07

  • Closed date

    2013-10-03

  • Last modified date

    2013-11-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK98177 UK98178

Modules/Macros

  • INZOBASE INZPLIB0 INZTPMEM INZUTILK INZUTILX
    

Fix information

  • Fixed component name

    DB2 HI PERF UNL

  • Fixed component ID

    5697F4400

Applicable component levels

  • R410 PSY UK98177

       UP13/10/16 P F310

  • R420 PSY UK98178

       UP13/10/16 P F310

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUV","label":"IBM Db2 High Performance Unload for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021