IBM Support

PM93595: ABN=5C6-00D4002F CSQNSINF+000002E4 AFTER UPGRADE TO WMQ V710

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After queue manager was upgraded from WMQ v701 to v710, an SVC
    dump is generated during queue manager start-up.  The queue
    manager and CHINIT still came up successfully.  The queue
    manager was re-cycled later but it still took an SVC DUMP
    when it was re-started.
    .
    DUMP TITLE=CSQ1,ABN=5C6-00D4002F,U=QT93MSTR,C=R3600.710.CMD -CS
               QNSINF,M=CSQGFRCV,LOC=CSQMLPLM.CSQNSINF+000002E4
    .
    The change team found that the 5C6-00D4002F ABEND issued by
    CSQNSINF occurs when there are commands in the CSQINPT input
    dataset (e.g. ALTER SUB in the customer's case) and the
    queue-manager has command events enabled, but the
    SYSTEM.ADMIN.COMMAND.EVENT has not been defined locally.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend 5C6-00D4002F in CSQNSINF occurs   *
    *                      at queue manager startup, and whenever  *
    *                      PSMODE is changed from DISABLED to      *
    *                      COMPAT or ENABLED.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    While processing a command (for example DEFINE SUB) from the
    CSQINPT DD, a command event message was generated due to command
    events (CMDEV) being enabled on the queue manager. If the
    command event message cannot be put to
    SYSTEM.ADMIN.COMMAND.EVENT (for example, if this queue doesn't
    exist, or is put disabled), CSQNSINF is called to save
    information about the command, so that the event message can be
    generated when the queue is available again.
    CSQNSINF attempts to validate the origin of the command, however
    it does not recognise CSQINPT as a valid origin and issues the
    reported abend.
    

Problem conclusion

  • CSQNSINF is changed to correctly handle commands that originated
    in CSQINPT.
    100Y
    CSQNSINF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM93595

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-07-23

  • Closed date

    2013-09-13

  • Last modified date

    2014-03-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK97568

Modules/Macros

  • CSQNSINF
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UK97568

       UP13/10/16 P F310

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: