A fix is available
APAR status
Closed as program error.
Error description
User completion code=4087 reason code=00000003 occurred during signal error processing when preceded by a signal endpage. The problem only occurs when the program is compiled with Enterprise PL/I. The program runs successfully when the same program is compiled with PL/I for MVS & VM.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Enterprise PL/I users of PRINT files * * * **************************************************************** * PROBLEM DESCRIPTION: User completion code = 4087 * * reason code = 00000003 * * occurred during signal error processing * * for a PRINT file. * * * **************************************************************** * RECOMMENDATION: Apply the PTF for this APAR. * * * **************************************************************** ABEND U4087 reason code=3 occurs when the following conditions hold true: - PL/I program has a PRINT file. - The number of lines written to the PRINT file equals the pagesize for the file. - A SIGNAL ERROR statement is processed and during this error processing, the ENDPAGE condition is raised. Part of the error processing is to flush out buffers of open output files. The ENDPAGE condition was raised during this phase, and this caused the U4087 reason code=3. The U4087 is an LE abend that indicates a recursive error was detected, and reason code=3 indicates that a language-specific condition handler was processing a condition (signal error) when a subsequent condition (endpage) was raised.
Problem conclusion
The Enterprise PL/I library has been modified to avoid raising the ENDPAGE condition when the ERROR condition is being processed.
Temporary fix
Comments
APAR Information
APAR number
PM93035
Reported component name
LE VA PL/I
Reported component ID
568819806
Reported release
780
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-07-16
Closed date
2013-09-11
Last modified date
2013-10-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK97455 UK97456 UK97457
Modules/Macros
IBMPSTOB
Fix information
Fixed component name
LE VA PL/I
Fixed component ID
568819806
Applicable component levels
R770 PSY UK97455
UP13/09/14 P F309
R780 PSY UK97456
UP13/09/14 P F309
R790 PSY UK97457
UP13/09/14 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.