IBM Support

PM91604: OMPE Collector subsystem ABEND U2008 RC=000C RSN=00000008

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND U2008 in XCF gateway issuing IXCCREAT to connect a member
    to XCF while the member is already connected.
    
    
    KO2Z999E  OM00 V511 Service error SSM=OMPEREQ /OMPEREQ
    ABEND=U2008 RSN=00000008 MODE=ABEND
    DUMP TITLE=COMPON=SSI,COMPID=5752SC1B6,ISSUER=IEFJSARR,
    MODULE=IEFJSRE1,ABEND=U2008,REASON=0000000,
    SNAME=OM00
    KO2Z808E  OM00 V511 SSM=KO2ZXCFB SR=BIND     failed RC=000C
    RSN=00000008/N/A
    KO2Z999E  OM00 V511 Service error SSM=OMPEXCF /OMPEXCF
    ABEND=U2008  RSN=80000036 MODE=ABEND
    KO2Z644E  OM00 V511 XCF service failed SSM=KO2ZXCF  ABEND=U2008
    RSN=80000036
    KO2Z999E  OM00 V511 Service error SSM=OMPEREQ /OMPEREQ
    ABEND=U2008 RSN=00000008 MODE=ABEND
    KO2Z639E  OM00 V511 XCF IXCCREAT request failed SSM=KO2ZSUB
    RC=000C RSN=00000008 CODE=00000000
    
    
    Additional Keywords
    IEFSSI KO2Z010E OMPEREQ RC=000C 000C RSN=00000008 00000008
    

Local fix

  • Please set XCFMODE=INACTIVE in RKD2PAR(OMPEOPTS).  This
    deactivates the XCF component.
    
    NOTE:
    If you haven't applied OA40035/UA67172(F212)=HKCI310, please do
    so, which will allow you to set XCFMOD=INACTIVE via PARMGEN
    process.
    
    UA67172 will provide a new WCONFIG(KD2$POP1) *KD2PAR(OMPEOPTS)
    via PARMGEN process.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON collector                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: OMPE Collector subsystem fails during   *
    *                      Initialization with ABEND U2008 and     *
    *                      RC=000C RSN=00000008.                   *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    OMPE Collector subsystem fails to locate the persistent system
    Level name/token during OMPE Collector initialization.
    
    PROBLEM CONCLUSION:
    Subsystem initialization has been changed to retrieve the
    Correct persistent system-level name/token pair.
    

Problem conclusion

  • Subsystem initialization has been changed to retrieve the
    Correct persistent system-level name/token pair.
    
    KEYWORDS : OMPEREQ KO2ZREQ KO2Z010E U2008 RC=000C,
               RSN=00000008
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM91604

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-21

  • Closed date

    2013-08-09

  • Last modified date

    2013-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK96568 UK96569

Modules/Macros

  • KO2ACAFA KO2ACAFK KO2ACAF2 KO2ACONB KO2AINIB
    KO2ARECB KO2CDCNB KO2CDFSA KO2CDFSK KO2CDFS2 KO2CIFBB KO2CIFIA
    KO2CIFIK KO2CIFI2 KO2CIF3A KO2CIF3K KO2CIF32 KO2CIF4A KO2CIF4K
    KO2CIF42 KO2CLKDA KO2CLKDK KO2CLKD2 KO2CMVSF KO2CTHBA KO2CTHBK
    KO2CTHB2 KO2CTHCA KO2CTHCK KO2CTHC2 KO2CTHEA KO2CTHEK KO2CTHE2
    KO2CTHGA KO2CTHGK KO2CTHG2 KO2CTHJA KO2CTHJK KO2CTHJ2 KO2CTHKA
    KO2CTHKK KO2CTHK2 KO2CTHLA KO2CTHLK KO2CTHL2 KO2CTHMA KO2CTHMK
    KO2CTHM2 KO2CTHNA KO2CTHNK KO2CTHN2 KO2CTHOA KO2CTHOK KO2CTHO2
    KO2CTHQA KO2CTHQK KO2CTHQ2 KO2CTHSA KO2CTHSK KO2CTHS2 KO2CTH2A
    KO2CTH2K KO2CTH22 KO2CTH3A KO2CTH3K KO2CTH32 KO2CT2SA KO2CT2SK
    KO2CT2S2 KO2DSPMB KO2GCAMB KO2HINTB KO2HSQPB KO2HSVIB KO2HWLMB
    KO2ICOLA KO2ICOLK KO2ICOL2 KO2LTCHB KO2NCSJB KO2NCSTB KO2NCS1B
    KO2NCS6B KO2NCS8B KO2NDRVB KO2OCMCB KO2ODBGB KO2OEVCB KO2OFUDB
    KO2OINTB KO2OMNUB KO2ORCVB KO2ORLGB KO2OSBSB KO2OSNPB KO2OSYXB
    KO2OSY1B KO2OTCIA KO2OTCIK KO2OTCI2 KO2OTHJB KO2OTHKB KO2OTHLB
    KO2OTHMB KO2OTHNB KO2OTHOB KO2OTHQB KO2OTHVB KO2OTHXB KO2OTHYB
    KO2OTH3B KO2OTH4B KO2OTH7B KO2OXSYB KO2OXTHB KO2PMSGF KO2SDMPB
    KO2WTCAA KO2WTCAK KO2WTCA2 KO2ZGTP  KO2ZINI  KO2ZISX  KO2ZREQ
    KO2ZTOP  KO2ZVTB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK96568

       UP13/08/13 P F308

  • R511 PSY UK96569

       UP13/08/13 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 September 2013