IBM Support

PM91453: INCORRECT COVER LETTER OR HOLD DATA FOR UK90686

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The cover letter or the ++HOLD DATA is incorrect for UK90686.
    
    The two new lock types already added to TEP in
    PM66755/UK82253(F210) / 5.1.0-TIV-KD5-IF0005 for v510.
    
    5.1.0-TIV-KD5-IF0005 is a v510 fixpack and does not apply to
    v511.
    
    
    You could apply the local fix shown below now.  After applying
    5.1.1-TIV-KD5-FP0001, apply local fix.  If you plan to apply
    5.1.1-TIV-KD5-FP0001 soon, then apply local fix after.
    

Local fix

  • Please download 5.1.1-TIV-KD5-FP0001 for non SDA users, apply
    PM83662/UK93093(F304) for SDA users.
    
    You could apply the local fix shown below now.  After applying
    5.1.1-TIV-KD5-FP0001, apply local fix.  If you plan to apply
    5.1.1-TIV-KD5-FP0001 soon, then apply local fix after.
    
    
    1)  The local fix below could be applied now or after
        5.1.1-TIV-KD5-FP0001
    
    Local fix:
    
    1. goto ...\cnps
    2. notepad dockdp and look for CICS_Release ( two occurances )
    3. add < *ENUM: 680=104 > to the end shown as follow
       *ATTR: CICS_Release
       *CAPTION: CICS\Release
       *COLUMN: CI_CICSREL
       *TYPE: I,4
       *ENUM: Unknown=0
       *ENUM: 410=65
       *ENUM: 420=66
       *ENUM: 510=81
       *ENUM: 520=82
       *ENUM: 530=83
       *ENUM: 610=97
       *ENUM: 620=98
       *ENUM: 630=99
       *ENUM: 640=100
       *ENUM: 650=101
       *ENUM: 660=102
       *ENUM: 670=103
       *ENUM: 680=104
    
    
    2)  If you are using v511 Agent, you should upgrade TEP and
        HTEMS to v511 app support then apply fixpacks if any, e.g.
        5.1.1-TIV-KD5-FP0001 for OMPE v511.
    
    3)  If TEPS and TEMS already at v511, the installer won't take
        5.1.0-TIV-KD5-IF0005 because it is at a lower version.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - Classic Interface                          *
    *                 - CUA Interface                              *
    *                 - TEP                                        *
    *                 - NTH - Near Term History                    *
    *                 - ATF - Application Trace Facility           *
    ****************************************************************
    * PROBLEM DESCRIPTION: The ++HOLD DATA is incorrect for        *
    *                      UK90686.                                *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    The ++HOLD DATA is incorrect for UK90686.
    5.1.0-TIV-KD5-IF0005 is a v510 fixpack and
    does not apply to v511.
    
    PROBLEM CONCLUSION:
    The ++HOLD DATA is corrected to address local fix in v511.
    
    KEYWORDS:
    INCORROUT ++HOLD DATA
    

Problem conclusion

  • The ++HOLD DATA is corrected to address local fix in v511.
    
    KEYWORDS:
    INCORROUT ++HOLD DATA
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM91453

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-19

  • Closed date

    2013-08-30

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK97173

Modules/Macros

  • KO2CLKDA KO2CLKDK KO2CLKD2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UK97173

       UP13/09/02 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: