Error description

  • Under IPCS,
    SELECT 2  : 2  ANALYSIS    - Analyze dump contents
    SELECT 6  : 6  COMPONENT   - MVS component data
    SELECT    : S CSQMAIN  WebSphere MQ dump formatter panel
    interface
    SELECT 3  : DUMPDATA SET: DSNAME('xxxxx.xxxxx.xxxx.DUMP')
    SELECT 8  : 8 Format and display the dump
    
    -- IBM WebSphere MQ for z/OS - FORMAT AND DISPLAY DUMP --
    COMMAND ===> 1
     1  Display the control blocks and trace
     2  Display just the control blocks
     3  Display just the trace
    Options:
      Use the summary dump ? . . . . . . . . . . .  1_   1  Yes
      Subsystem name . . . . . . . . . . . . . . .  ____
      Address space identifier or ALL. . . . . . .  ALL_
    ERROR MESSAGE: CSQW007E - OPERAND IS NOT VALID: SUMDUMP=YES
    is issued.
     There is a problem with the validation of the SUMDUMP parameter
    performed by CSQWD710.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: CSQMAIN dump formatter does not         *
    *                      correctly display formatter output when *
    *                      summary dump data is used.              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When using the CSQMAIN dump formatter from within IPCS, the
    "Format and display the dump" option (8) will display the
    following error when attempting to format a dump and requesting
    the summary dump data be formatted:
    
    CSQW007E - OPERAND IS NOT VALID: SUMDUMP=YES
    

Problem conclusion

  • The IPCS panel has been amended to ensure that the correct
    parameters are passed to the formatter and the error does not
    appear.
    100Y
    CSQ7DUMP
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM91056

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-06-13

  • Closed date

    2013-06-26

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK95457

Modules/Macros

  • CSQ7DUMP
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UK95457

       UP13/08/23 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.