Error description

  • The discovery utility HKTDDSC0 function CREATE is supposed to
    not only build a new inventory but also refresh an existing
    existing inventory. Looks like this is not the case
    The inventory has to be DELETEd and then CREATEd to take into
    account a partition that has been added to a HALDB, so we are
    able to see it from the Admin Console.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM TOOLS AUTO DISCOVERY UTILITY HKTDDSC0    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The FUNC=CREATE function doesn't        *
    *                      refresh existing discovery records      *
    *                      in the HKT_INPUT repository.            *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    HKTDDSC0 was changed to perform a DELETE of all the existing
    DISC records in the HKT_INPUT repository before executing the
    CREATE function.
    

Problem conclusion

  • Fixed.
    This apar also fix an abend0C4 or any other 0Cx abend in
    HKTDDSC0 when there are inconsistency between the DBDLIB
    and RECON about a database organization.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM90881

  • Reported component name

    TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-06-11

  • Closed date

    2013-10-21

  • Last modified date

    2013-11-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK98673 UK98674

Modules/Macros

  • HAHN130J HAHN140J HKTDAPI0 HKTDBLDB HKTDBLGP HKTDDIR0 HKTDDSC0
    HKTDDYA0 HKTDELDB HKTDELGP HKTDGRID HKTDREC0 HKTDWRDB HKTDWRGP
    IAVDSDSG
    

Fix information

  • Fixed component name

    TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R130 PSY UK98673

       UP13/10/23 P F310

  • R140 PSY UK98674

       UP13/10/23 P F310

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]

Document Information

Modified date:
14 December 2020