Error description
For Monitor reporting IMS PA attempts to verify that it has valid and complete information for the initial DLA (non-database) call. If the initial call duration is zero it incorrectly assumes that it has incomplete data and assigns a default PSBname / Function of "I/O PCB GU". This is a forward fit of IMSPA V420 APAR PM88736.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.3 * **************************************************************** * PROBLEM DESCRIPTION: IMS PA Monitor Program Analysis reports * * may incorrectly assign calls to * * PSBname/Function of "I/O PCB GU" * **************************************************************** * RECOMMENDATION: * **************************************************************** For Monitor reporting IMS PA attempts to verify that it has valid and complete information for the initial DLA (non-database) call. If the initial call duration is zero it incorrectly assumes that it has incomplete data and assigns a default PSBname/Function of "I/O PCB GU".
Problem conclusion
Expand initial DLA call validation when the duration is zero so as not to overwrite valid call data. Also, Sundry dialog validation and help updates.
Temporary fix
Comments
APAR Information
APAR number
PM88740
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-05-09
Closed date
2013-05-22
Last modified date
2013-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK94498
Modules/Macros
IPI#R5GR IPI#R5LI IPI#R5PR IPIACLND IPIRSL5 IPIRSL5A IPIRSS5 IPIRSS5A IPIRST2 IPIRST4 IPIRST6 IPISAPAR
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R430 PSY UK94498