Error description

  • 'FPEU0101S  INTERNAL ERROR IN MODULE FPEUFWMG' error message
    followed by 'FPEV0275E  MSTR ERROR WHEN PREPARING PE SERVER
    SUBTASK. MONITORING FOR DB2 SUBSYSTEM DB2E IS DISABLED' error
    message, which disables all ssids getting those messages.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: During start up the PE Server subtask   *
    *                      issues message FPEU0101S.               *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    During start up the PE Server subtask encounters a syntax error
    in a member of the configuration parameter data set and tries
    to issue message FPEV00019E to report the error. Preparation of
    the message text fails because of a data type mismatch of a
    passed message variable and the internal error message
    FPEU0101S is issued.
    
    
    PROBLEM CONCLUSION:
    The data type of the passed message variable has been
    corrected.
    

Problem conclusion

  • The data type of the passed message variable has been
    corrected.
    
    KEYWORDS : FPEU0101S INTERNAL ERROR FPEUFWMG
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM85145

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-03-19

  • Closed date

    2013-04-05

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK93175

Modules/Macros

  •    DGOVMSTR DGOVPP0  DGOVPP1  DGOVPP2  DGOVPP3
    DGOVPP4  DGOVPP5
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UK93175

       UP13/04/10 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]