IBM Support

PM85025: DYNAMIC ENABLEMENT OF SPMON USING OPERATOR COMMAND DOES NOT WORKPROPERLY IF OMPE COLLECTOR IS STARTED WITH SPMON=N

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the OMPE Collector is started with the Stored Procedure
    Monitoring feature disabled, enabling the Stored Procedure
    Collector task using the operator command /F <collector-stc>, f
    peserver, f <ssid>,SPMON=Y does not show the desired effect of
    seeing stored procedure related monitoring data in the SQL
    Dashboard or Extended Insight Analysis dashboard.
    

Local fix

  • Start the OMPE Collector with SPMON=Y and then disable the
    feature after startup, in case it is not needed and should be
    dynamically turned on at a later point in time.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    *                 -   Users of the Stored Procedure Monitoring *
    *                     functionality in the Web Console (OPM)   *
    ****************************************************************
    * PROBLEM DESCRIPTION: If the OMPE Collector is started with   *
    *                      the Stored Procedure Monitoring         *
    *                      feature disabled, enabling the Stored   *
    *                      Procedure Collector task using the      *
    *                      operator command /F <collector-stc>,    *
    *                      f peserver, f <ssid>,SPMON=Y does not   *
    *                      show the desired effect of seeing       *
    *                      stored procedure related monitoring     *
    *                      data in the SQL Dashboard or Extended   *
    *                      Insight Analysis dashboard.             *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    If the OMPE Collector is started with the Stored Procedure
    Monitoring feature disabled, enabling the Stored Procedure
    Collector task using the operator command /F <collector-stc>,
    f peserver, f <ssid>,SPMON=Y does not show the desired effect of
    seeing stored procedure related monitoring data in the SQL
    Dashboard or Extended Insight Analysis dashboard.
    
    PROBLEM CONCLUSION:
    The problem described has been resolved.
    

Problem conclusion

  • The problem described has been resolved.
    
    KEYWORDS : SPMON SP MONITORING
    

Temporary fix

  • Start the OMPE Collector with SPMON=Y and then disable the
    feature after startup, in case it is not needed and should be
    dynamically turned on at a later point in time.
    

Comments

APAR Information

  • APAR number

    PM85025

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-18

  • Closed date

    2013-03-25

  • Last modified date

    2013-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DUMM7KO2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UK92867

       UP13/03/28 P F303

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]