Error description

  • SMUI TLLK TCB ABEND S0C4, MODULE=LLKSND24
    ABEND0C4 in GJEULLK0 when IMS Sysplex Manager loops through
    locks to add waiters to AWE spool block.  The spool block
    overflows across an allocated page boundary.  R11 points to the
    last valid block address before the page boundary.
    
    Additional symptom of this issue:
    Storage overflow causes S0C4 PIC11 with routine GJEHYDS in
    control, when trying to access R14 storage. PMR 04525,79L,000
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All SM users                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 GJEULLK0 and ABEND0C4 GJEHYDS  *
    *                      take down SM UI server address space.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When there are too many lock waiter entries, storage overflow
    occurs in the AWE spool block and history logging block.
    

Problem conclusion

  • Code was added to limit the # of waiter entries logged to
    prevent the overflow condition. This also includes a fix for
    an abend0c4 in GJEAOE0X during IMS initialization.
    SM UI server address space needs to be recycled after applying
    this fix.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM84674

  • Reported component name

    IMS SYSPLEX MGR

  • Reported component ID

    5655P0100

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-03-12

  • Closed date

    2013-05-20

  • Last modified date

    2015-04-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK94443

Modules/Macros

  • GJEAOE0A GJEAOE0B GJEAOE0C GJEAOE0D GJEAOE09 GJEHYDS  GJEULLK0
    

Fix information

  • Fixed component name

    IMS SYSPLEX MGR

  • Fixed component ID

    5655P0100

Applicable component levels

  • R130 PSY UK94443

       UP13/05/22 P F305

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Sysplex Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
23 April 2015