IBM Support

PM84374: ABENDU4013 AND MSGFABH0322E ARE ISSUED WHEN HALDB OSAM BLOCK SIZE IS NOT THE SAME SIZE DEFINED IN RECON.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDU4013 and MSGFABH0322E are issued when HALDB OSAM block
    size is not the same size as defined in RECON.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Unload *
    *                 for z/OS Version 1 Release 2 (FMID=H1IN120). *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDU4013 and MSGFABH0322E are issued  *
    *                      in the module FABH002                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    ABENDU4013 and MSGFABH0322E (S-C DOES NOT MATCH) are issued in
    the module FABH002 when the actual BLKSIZE of a HALDB OSAM is
    not the same as that registered to the RECON.
    

Problem conclusion

  • HP Unload has been modified to issue MSGFABH0607I and to
    continue processing when the actual BLKSIZE of a HALDB OSAM is
    not the same as that registered to the RECON.
    
    ========================
    = Documentation Change =
    ========================
    IBM IMS High Performance Unload for z/OS, V1R2, User's Guide
    (SC27-0936-07) should be changed as follows:
    ================================================================
    7.2 Messages and codes
    7.2.4 Messages
    7.2.4.1 FABH essages
    
     Two new messages are added.
    ----------------------------------------------------------------
    | FABH0607I DD=dd_name BLOCK SIZE IS NOT SIZE DEFINED IN RECON
    |
    | Explanation: The actual block size of the indicated OSAM
    | data set is not the same as that registered to the RECON.
    | System Action: The processing continues.
    | User Response: It is recommended that the block size is
    | corrected.
    ----------------------------------------------------------------
    | FABH0608E RANSIZE IS TOO LOW: MINIMUM IS nnn
    |
    | Explanation: The value of a RANSIZE control statement is lower
    | than the acceptable minimum value.
    | System Action: HSSR Engine ends abnormally.
    | User Response: Correct the control statement.
    ----------------------------------------------------------------
    ================= End of Documentation Change ==================
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM84374

  • Reported component name

    IMS HIGHPERF UN

  • Reported component ID

    5655E0600

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-03-07

  • Closed date

    2013-03-27

  • Last modified date

    2013-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK92967

Modules/Macros

  •    FABH512
    

Fix information

  • Fixed component name

    IMS HIGHPERF UN

  • Fixed component ID

    5655E0600

Applicable component levels

  • R120 PSY UK92967

       UP13/03/29 P F303

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date: