A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C2 REASON CODE=00000002 at FPQCSRVX+8478
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Tools Base 1.3 - component ITKB and * * Policy Services. * **************************************************************** * PROBLEM DESCRIPTION: IMS tools that use the FPQ server * * may abend with : * * ABENDS0C2 REASON CODE=00000002 at * * FPQCSRVX+8478 * **************************************************************** * RECOMMENDATION: After installing the APAR - issue next * * command - to replace FPQCXCF2 in LPA * * (if no IPL ) * * * * SETPROG LPA,DELETE,MODNAME(FPQCXCF2), * * FORCE=YES CURRENT * * SETPROG LPA,ADD,MODNAME(FPQCXCF2), * * DSNAME(hlq.SHKTLOAD) * * If IPL - the new copy will be used * **************************************************************** Tools call for FPQ sevices in Problem or Suprvisor state. If FPQ initialization is in Supervisor state - the FPQ stacking PC is not found and saved in the anchor block for further references, Next calls may abend if executed in Problem state, because the stacking PC address is 0.
Problem conclusion
The program is fixed to find and save the stacking PC on init call in all states.
Temporary fix
Comments
APAR Information
APAR number
PM83951
Reported component name
TOOLS BASE
Reported component ID
5655V9300
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-03-01
Closed date
2013-03-05
Last modified date
2013-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK92242
Modules/Macros
FPQCSLT
Fix information
Fixed component name
TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R130 PSY UK92242
UP13/03/06 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]
Document Information
Modified date:
19 October 2020