A fix is available
APAR status
Closed as new function.
Error description
IMSPA plans to improve the functionality and flexibility of OMEGAMON ATF reporting by enhancing the MONITOR report option that controls the processing of IMS monitor (SLOG) events in the ATF Trace report (levels 2 and 3 only). ATF has two record types dedicated to IMS monitor events: - x'03' for Fast Path - x'06' for Full Function Currently the type x'03' FP is reported by default, and it is always reported. Reporting of the type x'06' is controlled by the MONITOR report option for Trace levels 2 & 3. Both monitor types will now be controlled by the MONITOR report option: - When MONITOR is specified, the FP and FF monitor events are reported in the ATF trace levels 2 and 3. - When MONITOR is not specified, the FP and FF monitor events are not reported in the trace. This is the default. This change will affect the way IMSPA operates. Existing ATF trace report requests will no longer report Fast Path monitor events (ATF type x'03') by default, this is controlled by the MONITOR option. The ATF Trace level 2 & 3 reports will be enhanced for the MONITOR option to include additional fields and expanded information.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.3 * **************************************************************** * PROBLEM DESCRIPTION: Improve functionality and flexibility * * of OMEGAMON ATF reporting * **************************************************************** * RECOMMENDATION: * **************************************************************** Improve the functionality and flexibility of OMEGAMON ATF reporting by enhancing the MONITOR report option that controls the processing of IMS monitor (SLOG) events in the ATF Trace report (levels 2 and 3 only).
Problem conclusion
Temporary fix
Comments
ATF has two record types dedicated to IMS monitor events x'03' for Fast Path x'06' for Full Function Currently the type x'03' FP is reported by default , and it is always reported. Reporting of the type x'06' is controlled by the MONITOR report option for Trace levels 2 & 3. Both monitor types will now be controlled by the MONITOR report option: When MONITOR is specified, the FP and FF monitor events are reported in the ATF trace levels 2 and 3. When MONITOR is not specified, the FP and FF monitor events are not reported in the trace. This is the default. The ATF Trace level 2 & 3 reports will be enhanced for the MONITOR option toinclude additional fields and expanded information.
APAR Information
APAR number
PM83151
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
430
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2013-02-19
Closed date
2013-03-06
Last modified date
2013-08-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK92268
Modules/Macros
IPIOTRAC IPISAPAR
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R430 PSY UK92268
UP13/03/09 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"","label":""}}]