A fix is available
APAR status
Closed as new function.
Error description
Support for the IMS Cloning Tool's ISPF interface.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All DBCS users who want to launch the IMS * * Cloning Tool's ISPF Dialog. * **************************************************************** * PROBLEM DESCRIPTION: The IMS Cloning Tool's ISPF Dialog * * could not be launched from the DBCS * * main menu. * **************************************************************** * RECOMMENDATION: * **************************************************************** A new option "K" was added to the DBCS main menu to launch the IMS Cloning Tool as shown below.Ensure that the IMS Cloning Tool's data set name is defined during the "Set up environment" process. IDLP00 IMS DB CONTROL SUITE V3.2 - PM82478 for CS ID CSV13 IMS Version 13.1 Command ===> Select a task or press END to exit Tasks . . 1. Set up environment 2. Run jobs 3. Maintain RECON 4. System administration ISPF links to other IMS tools A. IMS library integrity checking B. IMS HP Pointer Checker: IMS DB Repair C. IMS HP Change Accum D. IMS HALDB Toolkit E. IMS Command Control Facility F. Tools Base: IMS Tools Knowledge Base G. Tools Base: Policy Services H. Tools Base: IMS Hardware Data Compression I. Infosphere Guardium Data Encryption J. Recovery Expert K. IMS Cloning Tool
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PM82478
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
320
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-08
Closed date
2013-02-21
Last modified date
2013-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK91887
Modules/Macros
IDL$IHPA IDL$IHPE IDLCS11 IDLCS110 IDLC0001 IDLC50 IDLP00
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R320 PSY UK91887
UP13/02/26 P F302
Fix is available