IBM Support

PM82308: SE-Wizard quits SD generation if Fork Bar has multiple flows to Call behaviour

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Headline:
    The SE-Wizard quits sequence diagram generation if you have a
    Fork bar that has flows going to more than one call behavior.
    
    
    Abstract:
    Attempts to generate SD through an SE-Wizard results in failure
    if there exists a fork with multiple flows to call behaviours.
    
    
    error_description:
    The issue occurs when you have a Fork bar that has flows going
    to more than one call behavior - there is an error in the
    reference counting of call behaviors in the code
    
    
    workaround:
    Have only one call behavior as the direct  target of a fork -
    replace the others with actions - call behaviour.
    
    
    Attachments:
    SEToolkitIssue.zip contins the sample model. Right-click inside
    the Main Activity and select SE Toolkit ? Generate Sequence
    Diagrams to reproduce it
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SEToolkit: Wizard quits SD generation if Fork Bar has
    multiple flows to Call behaviour
    

Problem conclusion

  • Fixed in 8.0.5
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM82308

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-07

  • Closed date

    2013-12-11

  • Last modified date

    2013-12-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R800 PSN

       UP