Error description

  • AbendS0C1 or S0C4 may occur when more than one subtask is in
    use in the target job and log apply is processing multiple pages
    concurrently.
    Access to a linked list of logs used by all subtasks is not
    single threaded.  This can result in the list being corrupted,
    which in turn can result in an ABEND S0C1 or S0C4. The code will
    be changed to single thread access to the list.
    

Local fix

  • Rerun the failing job with MAX-SUBTASK=1.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: AbendS0C1 or S0C4 may occur when more   *
    *                      than one subtask is in use in the       *
    *                      target job and log apply is processing  *
    *                      multiple pages concurrently. Access to  *
    *                      a linked list of logs used by all       *
    *                      subtasks is not single threaded.  This  *
    *                      can result in the list being corrupted, *
    *                      which in turn can result in an ABEND    *
    *                      S0C1 or S0C4. The code will be changed  *
    *                      to single thread access to the list.    *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM81186

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-01-22

  • Closed date

    2013-07-01

  • Last modified date

    2013-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK95564

Modules/Macros

  • CKZ$ACES CKZ$BDSN CKZ$BMSG CKZ$BOOT CKZ$BUTJ CKZ$CAF  CKZ$CAFA
    CKZ$CALL CKZ$CTCM CKZ$DCMD CKZ$DCVT CKZ$ERR  CKZ$ESTA CKZ$GSKB
    CKZ$INFO CKZ$LOG  CKZ$PRFD CKZ$PRFR CKZ$SMSG CKZ$SPRM CKZ$SQLC
    CKZ$SQL2 CKZ$TOK  CKZ$TSOC CKZ$ZPAR CKZ#AMIN CKZ#ASYS CKZ#CARD
    CKZ#CHKR CKZ#CL   CKZ#CL64 CKZ#CL7  CKZ#CL8  CKZ#CMET CKZ#CNTL
    CKZ#CNVT CKZ#CN64 CKZ#CPM  CKZ#CPNT CKZ#CPOL CKZ#DB2V CKZ#DCAT
    CKZ#DSAF CKZ#DSPL CKZ#DSQL CKZ#ENQS CKZ#ENVF CKZ#EPRI CKZ#HTAB
    CKZ#ICAI CKZ#ICAL CKZ#ICCC CKZ#ICCI CKZ#IDCF CKZ#IDSA CKZ#IERR
    CKZ#IHSA CKZ#IKPL CKZ#IKPN CKZ#ILGP CKZ#ILRA CKZ#ILRS CKZ#ILSA
    CKZ#IOPF CKZ#IPIE CKZ#IPPB CKZ#IPPC CKZ#IPPD CKZ#IPPH CKZ#IPPL
    CKZ#IPPN CKZ#IPPS CKZ#IRPL CKZ#ISNA CKZ#JPRI CKZ#JUST CKZ#JU64
    CKZ#LGAA CKZ#LGAC CKZ#LGAF CKZ#LGAI CKZ#LGAP CKZ#LGRN CKZ#LIKE
    CKZ#LOGR CKZ#LRDR CKZ#LRD6 CKZ#MAIN CKZ#MLOG CKZ#MPRI CKZ#MREP
    CKZ#OPRI CKZ#OUT2 CKZ#PARS CKZ#PRNG CKZ#QCAT CKZ#RANG CKZ#RCAT
    CKZ#REPO CKZ#RESM CKZ#RM24 CKZ#RPRP CKZ#RUNT CKZ#SQLC CKZ#SQL2
    CKZ#STAT CKZ#STCK CKZ#STMT CKZ#SUBD CKZ#SUBS CKZ#SUBX CKZ#SYSC
    CKZ#TB   CKZ#TB7  CKZ#TB8  CKZ#TSS  CKZ#TSSA CKZ#UCBS CKZ#UPRI
    CKZ#UTLB CKZ#UTLC CKZ#UTOP CKZ#VSAM CKZ#VSA1 CKZ#VSA2 CKZ#WRIT
    CKZ#XMLD CKZ#XMLS CKZ@CAF  CKZ@CAFA CKZ@CAFW CKZ@CNUM CKZ@COLS
    CKZ@CSCR CKZ@DBC  CKZ@DSN  CKZ@DSQL CKZ@EXP1 CKZ@FIX1 CKZ@FORM
    CKZ@LOGR CKZ@ORD1 CKZ@REM1 CKZ@RES1 CKZ@ROLB CKZ@SCCM CKZ@SCGT
    CKZ@SCIT CKZ@SCPT CKZ@SCRL CKZ@SCR1 CKZ@SFND CKZ@SIZ1 CKZ@SMSG
    CKZ@SQLD CKZ@SRT1 CKZ@SSET CKZ@SSRT CKZ@USRT CKZALLZT CKZAPOST
    CKZASML  CKZBLNKT CKZCAPST CKZCHART CKZCNVTP CKZCOMAT CKZDAREA
    CKZDBC   CKZDBCA  CKZDBCH  CKZDBCX  CKZDBHP  CKZDGRP  CKZDGRPS
    CKZDOTT  CKZDYNAL CKZFILTR CKZFTRT  CKZHEXT  CKZHLI   CKZHLI2
    CKZIALI  CKZIDB2C CKZIDCAM CKZIENQS CKZIEXCP CKZIGIDX CKZIGRS
    CKZIHFP  CKZIHLI2 CKZIICW2 CKZIIDPH CKZIIKS  CKZIIKSA CKZILOCK
    CKZIMAIN CKZIMSGS CKZIMUTX CKZINCRD CKZIPAGE CKZIPROT CKZIPSRW
    CKZIRBLT CKZIROWK CKZISMPR CKZISORT CKZISOR1 CKZISOR2 CKZISOR3
    CKZISOR5 CKZISTDB CKZISYSP CKZITHRD CKZIUCB  CKZIUTLB CKZIVSAD
    CKZIVSAM CKZIVSAS CKZIXCON CKZIXDEC CKZIXIND CKZIXMAT CKZIXMLR
    CKZIXNOD CKZIXREC CKZLINKL CKZLOGR  CKZLVALT CKZMMIF  CKZMSRT
    CKZNBLKT CKZNNUMT CKZPARET CKZPERIT CKZRDPDS CKZRPART CKZSLIP
    CKZSLST  CKZSRT64 CKZSVC26 CKZS99   CKZTOKEN CKZUNICN CKZUNIGT
    CKZZPEXT CKZ00235 CKZ00501 CKZ00510 CKZ00527 CKZ00530 CKZ00532
    CKZ00535 CKZ00536 CKZ00537 CKZ00546 CKZ00547 CKZ00549 CKZ00600
    CKZ00612 CKZ00630 CKZ00710 CKZ00730 CKZ00760 CKZ00762 CKZ00763
    CKZ00764 CKZ00765 CKZ10CMD CKZ7CMD  CKZ8CMD  CKZ9CMD  HCKZ310J
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R310 PSY UK95564

       UP13/07/10 P F307

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
31 March 2021