APAR status

  • Closed as program error.

Error description

  • DB2 Administration Tool for z/OS does not remove BL2ELIB when it
    is blanked out
    during installation process using Tools Customizer for z/OS
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DB2 Administration Tool and     *
    *                 IBM Tools Customizer (TCz) for z/OS.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.  The following input fields on       *
    *                      panel CCQPDB2 'DB2 Parameters' can not  *
    *                      be blanked out:                         *
    *                                                              *
    *                      DB2 load library                        *
    *                      DB2 run library                         *
    *                      DB2 message library                     *
    *                      DB2 panel library                       *
    *                      DB2 skeleton library                    *
    *                      DB2 table library                       *
    *                      DB2 REXX EXEC library                   *
    *                      DB2 CLIST library                       *
    *                                                              *
    *                      2.  When customizing TCz on panel       *
    *                      CCQPDB2, 'DB2 Parameter' or panel       *
    *                      CCQPPRD 'Product Parameters', and       *
    *                      specifying a value for the 'DB2         *
    *                      Table Editor CLIST dsname(member)'      *
    *                      field, and YES to enable the DB2        *
    *                      Table Editor Tool, the ADBCUSAA job     *
    *                      reports the following error:            *
    *                                                              *
    *                      subsys keyword pos dataset name         *
    *                      error description                       *
    *                      --------------------------------------  *
    *                       *    ADBTECL   1 >hlq<.SETISAMP(ETI)'  *
    *                      Member name not allowed                 *
    *                       >ssid< ADBTECL 1 >hlq<.SETISAMP(ETI)'  *
    *                      Member name not allowed                 *
    *                      --------------------------------------  *
    *                                                              *
    *                      3.  If user enables InfoSphere Optim    *
    *                      Configuration Manager (OCM) tasks and   *
    *                      steps through panel CCQPPRD 'Product    *
    *                      Parameter', it then enables the hidden  *
    *                      OCM options in panel CCQPDB2 'DB2       *
    *                      Parameters', and the 'Action to take on *
    *                      error' field is pre-filled with the     *
    *                      LOCAL value.  The jobs are incorrectly  *
    *                      built with the default value of LOCAL   *
    *                      instead of the option specified in the  *
    *                      '(Global) Action to take on error'      *
    *                      field, which has OVERRIDE.              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The following input fields on panel CCQPDB2 'DB2 Parameters'
    can not be blanked out:
    
    DB2 load library
    DB2 run library
    DB2 message library
    DB2 panel library
    DB2 skeleton library
    DB2 table library
    DB2 REXX EXEC library
    DB2 CLIST library
    
    2.  When customizing TCz on panel CCQPDB2, 'DB2 Parameter'
    or panel CCQPPRD 'Product Parameters', and specifying a
    value for the 'DB2 Table Editor CLIST dsname(member)' field,
    and YES to enable the DB2 Table Editor Tool, the ADBCUSAA
    reports the following error:
    
    subsys keyword pos dataset name            error description
    ---------------------------------------------------------------
    *  ADBTECL   1 >hlq<.SETISAMP(ETI)'    Member name not allowed
    >ssid< ADBTECL 1 >hlq<.SETISAMP(ETI)'  Member name not allowed
    ---------------------------------------------------------------
    
    3.  If user enables InfoSphere Optim Configuration Manager
    (OCM) tasks and steps through panel CCQPPRD 'Product
    Parameter', it then enables the hidden OCM options in panel
    CCQPDB2 'DB2 Parameters', and the 'Action to take on error'
    field is pre-filled with the LOCAL value.  The jobs are
    incorrectly built with the default value of LOCAL instead of
    the option specified in the '(Global) Action to take on error'
    field, which was OVERRIDE.
    

Problem conclusion

  • Problem has been resolved
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM80850

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    A20

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-17

  • Closed date

    2013-02-05

  • Last modified date

    2013-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK91421

Modules/Macros

  •    GOC$$CCQ
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • RA20 PSY UK91421

       UP13/02/08 P F302

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]