PM79738: Property editing causes editor to go blank

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When editing properties, the editor canvas goes blank. For
    example, when the user changes the drop down menu background
    color from cyan to dark red the editor goes blank afterwards.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The egl.rootHandler is not cleared when the reloadHandler
    function is executed in the VE JavaScript runtime. When
    users explicitly use egl.rootHandler in the startupInit
    function, it's not null as expected.
    

Problem conclusion

  • The egl.rootHandler is not cleared when the reloadHandler
    function is executed in the VE JavaScript runtime. When
    users explicitly use egl.rootHandler in the startupInit
    function, it's not null as expected.
    Fixed egl_development.js to reset egl.rootHandler to null
    after reload handler.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM79738

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-26

  • Closed date

    2013-03-11

  • Last modified date

    2013-03-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R801 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
11 March 2013