Error description
The following problems are addressed: 1. Write event record to journal when a command has been issued to drain or resume a datastore, or a datastore has been "autoresumed". 2. Provide a way to report the number of outstanding responses for a datastore. 3. Type 1 commands issued via IMS Connect Extensions being routed to wrong IMS Connect. 4. Incorrect data transmitted to Operations Console GUI client for some ODBM sessions. 5. Reduce the time that the Publisher API Buffer Lock is held by CEX. 6. The PROC= field for the type41 event record from the Print Utility can contain blanks. New flag bits have been added to OMCTLPFG that are not supported by the print utility. Reduce the time that the Publisher API Buffer Lock is held by CEX while moving event records to the buffer.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extentions V2.2 * **************************************************************** * PROBLEM DESCRIPTION: Reduce the time that the Publisher API * * Buffer Lock is held by CEX. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR is correcting the following: 1.Reduce the time that the Publisher API Buffer Lock is held by CEX. 2.The PROC= field for the type 41 event record from the Print Utility can contain blanks. New flag bits have been added to OMCTLPFG that are not supported by the print utility. 3.Provide toleration for IMS Connect APAR PM69983 which adds tracking token address and length to events 61 x'3D' and 62 x'3E'
Problem conclusion
The following changes have been made for the above issues: 1.Added additional latch to allow the CEX API server to reduce the amount of time it holds the Asynchronous buffer latch while moving event records to the buffer. 2.To be consistent with the rest of the report the PROC= is changed to contain a value of NONE when OMCTLPFG does not have flag bits set on. Support for new flag bit setting is also added 3.Changed the event record macros for events 61 and 62 to support the new fields and included support for the new fields in the print utility.
Temporary fix
Comments
APAR Information
APAR number
PM77548
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
220
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-11-21
Closed date
2012-12-10
Last modified date
2013-01-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK90185
Modules/Macros
CEXAPIUT CEXAPMT1 CEXCERE CEXCMDEV CEXCONSP CEXCR00 CEXCR61 CEXCR62 CEXCVDB CEXDFN1 CEXEVTPR CEXEVT01 CEXEVWTR CEXIICB CEXJRNEX CEXMAIN CEXMAPI CEXPBAC CEXPC01 CEXPRED0 CEXPRED1 CEXPUBMN CEXRAPR CEXR172 CEXSALUT CEXTECL CEXTPXML
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R220 PSY UK90185
UP12/12/13 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date:
22 October 2020