Error description
There are several parameters in DSNZPARM that allow sites to specify flash copy as a default. For image copies this parameter is FLASHCOPY_COPY. The site must also specify a default template in DSNZPARM for the dataset name. DB2 COPY syntax allows for users to override the default setting, to always take a flash copy, by specifying FLASHCOPY NO on the utility control statement. However, this option is not available in the Automation Tool utility profile. Hence when the DSNZPARM parameter is 'FLASHCOPY_COPY YES', the only way that a user can override this is to manually edit the JCL produced by Automation Tool. . This enhancement will provide an Automation Tool option that will allow FLASHCOPY NO to be specified when flash copy is the default but a regular DB2 image copy is required.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: There are several parameters in * * DSNZPARM that allow sites to specify * * flash copy as a default. For image * * copies this parameter is FLASHCOPY_COPY * * The site must also specify a default * * template in DSNZPARM for the dataset * * name. DB2 COPY syntax allows for users * * to override the default setting, to * * always take a flash copy, by specifying * * FLASHCOPY NO on the utility control * * statement. However, this option is not * * available in the Automation Tool * * utility profile. Hence when the * * DSNZPARM parameter is 'FLASHCOPY_COPY * * YES', the only way that a user can * * override this is to manually edit the * * JCL produced by Automation Tool. This * * enhancement will provide an Automation * * Tool option that will allow FLASHCOPY * * NO to be specified when flash copy is * * the default but a regular DB2 image * * copy is required. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
Temporary fix
Comments
APPLY the PTF.
APAR Information
APAR number
PM77483
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
410
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-20
Closed date
2013-03-28
Last modified date
2013-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK92977
Modules/Macros
HAA$BDSN HAA$BUTC HAA$BUTI HAA$BUTR HAA$BUTX HAA$CALL HAA$CVT HAA$DCVT HAA$EXPF HAA$IMPF HAA$RIFO HAA$UCFO HAA$UCOP HAA$UIMG HAA$UOPT HAA$URCV HAA$UREO HAA$UREX HAA$UTSC HAA#BPRI HAA#UPRI HAA#UTED HAA#UTOP HAACOPYC HAAHRIFO HAAHUCFO HAAHUIMG HAAHURCV HAAHUREX HAAHVCFO HAAHVIFO HAAHVIMG HAAHVRCV HAAHVREX HAAM54 HAAM546E HAAM547E HAAM621E HAARBLDC HAAREOIC HAAREORC
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R410 PSY UK92977
UP13/04/05 P F304
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"","label":""}}]