Error description
In a 10 way IMS Datsharing Environment 4 systems were down for hardware upgrades when a Global Online Change was initiated with OPTION(FRCNRML). GOLC failed to complete on 1 of the 6 active systems. A QUERY MEMBER command shows a status of OLCCMT1C for this system indicating online change phase 1 completed. The other systems have completed phase 2 (OLCCMT2C), but are waiting for GOLC to complete on all systems. The OLCSTAT dataset has been corrupted with one duplicate entry and several missing entries.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS V12 users of global online * * change that use OPTION(FRCNRML) or * * OPTION(FRCABND) * **************************************************************** * PROBLEM DESCRIPTION: An INIT OLC PHASE(COMMIT) command * * corrupts the OLCSTAT dataset, if * * issued when IMSs are down, after * * INIT OLC PHASE(PREPARE) was specified * * with OPTION(FRCNRML). * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** An INIT OLC PHASE(PREPARE) TYPE(ACBLIB) OPTION(FRCNRML) command is issued and executes successfully, in the case where 4 IMSs were down because they were shut down with a a /CHE FREEZE command, and 6 IMSs were active. An INIT OLC PHASE(COMMIT) command is issued and commit phase 1 is performed successfully by all the active IMSs. The command master IMS then updates the OLCSTAT dataset incorrectly, corrupting it. The command master IMSID overlays the first IMSID in the OLCSTAT dataset, the last IMSID is incorrectly deleted, and the result is that the command master IMSID appears in the OLCSTAT dataset twice. This problem occurs if the number of IMSs in the OLCSTAT dataset is 4 or more and at least one of the IMSs is down. Each OLCSTAT dataset IMS entry is 80 bytes, so 80 x 4 = 320 bytes, which exceeds the maximum length allowed on a MVC instruction, so not all of the data is moved. This is why the commit command master appears in the new OLCSTAT dataset twice. Bypass: The IMSs that successfully completed commit phase 2 (QUERY MEMBER TYPE(IMS) SHOW(STATUS) displays status of OLCCMT2C), but whose IMSIDs disappeared from the OLCSTAT dataset (QUERY OLC LIBRARY(OLCSTAT) SHOW(ALL) doesn't display them in the MbrList field) can be added back to the OLCSTAT dataset with the Global Online Change Utility (DFSUOLC0) FUNC=ADD. The INIT OLC PHASE(COMMIT) command should be then issued again, to complete the Global Online Change for the IMSs that committed it, to get those IMSs out of an online change state, so that they can start doing work again, can participate in the next Global Online Change, and don't have to coldstart. The IMS commit command master whose IMSID is duplicated in the OLCSTAT dataset can have one of the IMSIDs removed with the DFSUOLC0 utility FUNC=DEL. The INIT OLC PHASE(COMMIT) command can be attempted again to complete the Global Online Change on this IMS and any others that failed to complete the Global Online Change.
Problem conclusion
GEN: KEYWORDS: *** END IMS KEYWORDS *** DFSOLC00 is corrected to use the MVCL instruction when moving the new OLCSTAT dataset contents to the old OLCSTAT dataset buffer, in case the length of the new OLCSTAT dataset contents exceeds 255 bytes, because of the count of IMSs in the old OLCSTAT dataset is 4 or more.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM75573
Reported component name
IMS V12
Reported component ID
5635A0300
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-10-22
Closed date
2012-12-03
Last modified date
2013-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK83959
Modules/Macros
DFSOLC00
Fix information
Fixed component name
IMS V12
Fixed component ID
5635A0300
Applicable component levels
R200 PSY UK83959
UP12/12/06 P F212
Fix is available